20
Connecting the grounding cable
Connect the grounding terminal of the AP to the grounding point with the yellow and green
grounding cable shipped with the AP, as shown in
Figure 3
. For more information about the
procedure, see “
Grounding and lightning protection
”.
NOTE:
If the AP is powered by a power injector, the PE output line of the power injector must also
be grounded.
Verifying the installation
After the installation and cabling, check the following items before powering on the AP:
The power source meets the power specification of the AP;
The AP is well grounded;
The power input cable and the Ethernet cables are correctly connected;
The outdoor antennas are installed;
If the AP is powered by a PoE+ switch, an Ethernet lightning arrestor (which is not shipped
with the AP) is installed on the AP.
Powering on the AP
Make sure that all the cables are correctly connected. Then, switch on the external power source
and check the power LED of the AP against
Table 2
.
CAUTION:
If the AP is installed outdoor, the Ethernet cable must be waterproof and the connection at
the AP port must be sealed with waterproof sealing tape.
Summary of Contents for WA2620X-AGNP