5
•
The WA2610i-GN supports 802.3af-compliant PoE. To achieve the best performance, H3C
recommends that you adopt GE connection to the power device.
•
Record the MAC address and serial number of the AP (marked on the rear of the AP) for future use.
Determining the installation position
Determine the installation position by observing the following principles:
•
Leave as few obstacles (such as wall) as possible between APs and clients.
•
Install APs away from electronic devices (such as microwave ovens) that may generate radio
frequency (RF) noise.
•
Install APs in a place where they will not hinder people’s daily work and life.
•
Do not install APs in a place where water seeping, water soaking, and condensing occur. Prevent
water or moisture from entering the APs.
CAUTION:
If part of the power line is routed outdoors, use a power strip with lightning protection (user supplied) to
connect the power cord of the AP to the power line to protect the AP from being damaged by lightning
strikes.
Installing the AP
NOTE:
The WA2610i-GN has integrated antennas. When you install the AP, determine whether external
antennas (user-supplied) are needed. Installing external antennas is not covered in this document.
Mounting the AP on a table
WARNING!
Do not place the WA2610i-GN on any metal surface. Place it on a place where there are no obstacles
and good signal strength is available.
1.
To mount the AP on a table, attach the rubber feet supplied with the AP to the rear of the AP.
Figure 4
Attach the rubber feet