6-32
14.
Power on the server. For more information, see "
Installing the NVMe VROC module
1.
Identify the NVMe VROC module connector on the management module. For more information,
see "Management module components."
2.
Power off the server. For more information, see "
3.
Disconnect all the cables from the management module.
4.
Remove the management module. For more information, see "
5.
Insert the NVMe VROC module onto the NVMe VROC module connector on the management
module, as shown in
.
Figure 6-38 Installing the NVMe VROC module
6.
Install the management module. For more information, see "
7.
Connect the power cord. For more information, see "
8.
Power on the server. For more information, see "
Installing a drive backplane
Guidelines
The installation locations of drive backplanes vary by drive configuration. For more information, see
"Drive configurations and numbering."
When installing a 4SFF NVMe drive backplane, paste the stickers provided with the backplane over
the drive number marks on the front panel of the corresponding compute module. This helps users
identify NVMe drive bays. Make sure the numbers on the stickers correspond to the numbers on the
front panel of the compute module. For more information about drive numbers, see "Drive
configurations and numbering."
Procedure
The procedure is the same for installing a 4SFF drive backplane and a 4SFF NVMe drive backplane.
This section uses a 4SFF drive backplane as an example.