Item 

Specifications 

 

(Optional.) Supports U-Center data center management platform 

Security 

Supports chassis intrusion detection, TCM/TPM module, two-factor authentication, and 

Intel PFR 3.0 and SGX 2.0 

Power and 

heat 

dissipation 

 

(Optional.) Platinum 

550W/800W/850W/1200W/1300W/1600W/2000W2400W/2700W  power supplies, 

supporting 1 + 1 redundancy 

 

(Optional.) -48VDC/336VDC 800W power supplies, supporting 1 + 1 redundancy 

 

(Optional.) Titanium CQC31-461288 certified grade V power supplies 

 

Support hot-swappable redundant fans 

Dimensions 

(H × W × D) 

2U chassis 

 

Without a security bezel:  

 

LFF&SFF models: 87.5 × 445.4 × 780 mm (3.44 × 17.54 × 30.71 in) 

 

E1.S model: 87.5 × 445.4 × 820 mm (3.44 × 17.54 × 32.28 in) 

 

With a security bezel:  

 

LFF&SFF models: 87.5 × 445.4 × 808 mm (3.44 × 17.54 × 31.81 in) 

 

E1.S model: 87.5 × 445.4 × 848 mm (3.44 × 17.54 × 33.39 in) 

Max. weight 

46.5 kg (102.51 lb) 

 

 

NOTE: 

[1] indicates a planned product specification. For information about the current available 

configuration, see the detailed product manuals. 

 

Operating environment requirements 

Item 

Specifications 

Operating temperature 

5 °C to 45 °C (41 °F to 113 °F), complying with ASHRAE class A4 
The operating temperature range varies by server model and 

configuration. For more information, see the detailed technical documents 

for the server. 

Storage temperature 

–40 °C to +70 °C (–40 °F to +158 °F) 

Operating altitude 

–60 m to +3000 m (–196.85 ft to +9842.52 ft) 
The allowed maximum temperature decreases by 0.33 °C (32.59 °F) as the 

altitude increases by 100 m (328.08 ft) from 900 m (2952.76 ft) 

Storage altitude 

–60 m to +5000 m (–196.85 ft to +16404.20 ft) 

 

In a rack stacking environment, the maximum temperature might  decrease because the cooling 

conditions are related with power density within racks and heat dissipation capacity of racks. 
 

Summary of Contents for UniServer R4900 G6 Ultra

Page 1: ...be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologies Co Ltd Except for the trademarks of New H3C Technologies Co Ltd any trademarks that may...

Page 2: ...ont 12LFF 8SAS SATA 4UniBay drive backplane 19 Front 12LFF4SAS SATA 8UniBay drive backplane 20 Front 12LFF UniBay drive backplane 20 Front 25SFF 17SAS SATA 8UniBay drive backplane 21 Front 16E1 S driv...

Page 3: ...ower fail safeguard modules 51 Storage controllers 51 Powerfail safeguard modules 51 Installation guidelines 52 NVMe VROC modules 53 Network adapters 53 GPU modules 53 Power supplies 54 Fan modules 55...

Page 4: ...ntelligence cloud desktop and other scenarios They are suitable for typical applications in industries such as Internet service providers finance enterprises and government The servers have the charac...

Page 5: ...to 36 U 2 NVMe solid state drives Supports up to 36 E3 S solid state drives Supports up to 32 E1 S solid state drives Supports up to 14 PCIe standard slots Supports 2 onboard OCP 3 0 slots Multi laye...

Page 6: ...DIMMs The server uses PCIe bus to connect to PCIe riser cards to provide PCIe slots of different specifications The servers support embedded OCP 3 0 network adapters for flexible configuration of PCIe...

Page 7: ...RAID configuration and RAID scale up It supports online upgrade of the controller firmware and remote configuration 6 NVMe VROC module Works with Intel VMD to provide RAID capability for the server t...

Page 8: ...TA M 2 SSD expander module Provides M 2 SSD slots 24 SATA M 2 SSD Provides data storage space for the server 25 Encryption module Provides encryption services for the server to enhance data security 2...

Page 9: ...8LFF front panel Table 1 8LFF front panel description Item Description 1 USB 3 0 connector 2 Drive or LCD mart management module optional 3 Serial label pull tab 4 Dedicated management connector 5 USB...

Page 10: ...ee Drive backplanes Figure 4 8SFF front panel Table 3 8SFF front panel description Item Description 1 Bay 1 8SFF drives optional 2 Bay 2 8SFF drives optional 3 Bay 3 8SFF drives optional 4 USB 3 0 con...

Page 11: ...dicated management connector 6 USB 2 0 connector 7 VGA connector Drive types supported by the server vary by drive backplane configuration For more information see Drive backplanes Figure 6 32E1 S fro...

Page 12: ...etwork adapter is receiving or sending data Off No link is present on any port of either OCP 3 0 network adapter NOTE The server supports a maximum of three OCP3 0 network adapters Health LED Steady g...

Page 13: ...m the middle to the two sides of the security bezel No load Less than 10 Light load 10 to 50 Middle load 50 to 80 Heavy load More than 80 Breathing white gradient at 1 Hz A pre alarm is present Flashi...

Page 14: ...riser bay 2 PCIe slots 4 through 6 3 PCIe riser bay 3 PCIe slots 7 and 8 4 PCIe riser bay 4 PCIe slots 9 and 10 5 Power supply 2 6 Power supply 1 7 OCP 3 0 network adapter Serial DSD module in slot 17...

Page 15: ...riser bay 4 PCIe slots 9 and 10 5 Power supply 2 6 Power supply 1 7 OCP 3 0 network adapter or serial DSD module in slot 17 optional 8 VGA connector 9 Two USB 3 0 connectors 10 HDM dedicated network p...

Page 16: ...he Ethernet port Steady green A link is present on the port Off No link is present on the port UID LED Steady blue UID LED is activated The UID LED can be activated by using the following methods Pres...

Page 17: ...age HDM from its Web interface Power receptacle Standard single phase Connects the power supply to the power source System board System board components Figure 12 System board components Table 13 Syst...

Page 18: ...age Detection module connector LEAKDET 18 LCD smart management module connector DIAG LCD 19 MCIO connector C1 P4A for processor 1 C1 P4A 20 MCIO connector C1 P4C for processor 1 C1 P4C 21 Fan connecto...

Page 19: ...drive backplane AUX4 47 Riser card AUX connector 8 AUX8 48 NVMe VROC module connector NVMe RAID KEY 49 Embedded USB 2 0 connector INTERNAL USB2 0 50 TPM TCM connector TPM 51 System battery 52 MCIO co...

Page 20: ...start up when the switch is turned on To avoid service data loss stop running services and power off the server before turning on the switch 6 Off default Normal server startup On Clears all passwords...

Page 21: ...the correspondence between the drive numbering of physical drives on the server and the drive numbering on HDM or BIOS see the server user guide Figure 15 Drive numbering for front 25SFF drive config...

Page 22: ...numbering for the rear OCP adapter configuration Figure 22 Drive numbering for the mid 4LFF drive configuration Figure 23 Drive numbering for the mid 8SFF drive configuration Drive LEDs The server su...

Page 23: ...n Flashing green 4 0 Hz The drive is operating correctly and is selected by the RAID controller Off Flashing green 4 0 Hz The drive is performing a RAID migration or rebuilding or the system is readin...

Page 24: ...SATA Y UniBay drive backplanes Support SAS SATA drives in all slots and support NVMe drives in certain slots X Number of slots supporting only SAS SATA drives Y Number of slots supporting both SAS SAT...

Page 25: ...nector POWER 5 MCIO connector B1 B2 PCIe5 0 x8 NVMe B1 B2 6 MCIO connector A3 A4 PCIe5 0 x8 NVMe A3 A4 7 MCIO connector A1 A2 PCIe5 0 x8 NVMe A1 A2 PCIe5 0 x8 description PCIe5 0 Fifth generation sign...

Page 26: ...backplane can be installed at the server front to support twelve 3 5 inch SAS SATA NVMe drives including eight SAS SATA drives and four SAS SATA NVMe drives Figure 30 12LFF 8SAS SATA 4UniBay drive ba...

Page 27: ...SAS PORT managing all drives on the backplane 2 x4 SlimSAS downlink interface 3 SAS EXP3 3 Power connector 2 PWR2 4 MCIO connector B1 B2 PCIe5 0 x8 NVMe B1 B2 supporting NVMe drives 6 and 7 5 Power co...

Page 28: ...CIe5 0 x4 NVMe C2 11 MCIO connector B3 B4 PCIe5 0 x8 NVMe B3 B4 12 MCIO connector A4 PCIe5 0 x4 NVMe A4 13 MCIO connector A1 A2 PCIe4 0 x8 NVMe A1 A2 PCIe5 0 x8 description PCIe5 0 Fifth generation si...

Page 29: ...and 18 8 AUX connector AUX 9 MCIO connector 3 PCIe5 0 x8 NVMe 3 supporting NVMe drives 19 and 20 10 MCIO connector 2 PCIe5 0 x8 NVMe 2 supporting NVMe drives 21 and 22 11 Power connector 3 PWR 3 12 M...

Page 30: ...ctor B1 B2 PCIe5 0 x8 EDSFF B1 B2 9 MCIO connector A3 A4 PCIe5 0 x8 EDSFF A3 A4 10 Power connector 2 PWR 2 11 MCIO connector A1 A2 PCIe5 0 x8 EDSFF A1 A2 PCIe5 0 x8 description PCIe5 0 Fifth generatio...

Page 31: ...r AUX 2 Power connector PWR 3 MCIO connector B1 B2 PCIe5 0 x8 NVME B1 B2 4 MCIO connector B3 B4 PCIe5 0 x8 NVME B3 B4 5 x4 Mini SAS HD connector SAS PORT PCIe5 0 x8 description PCIe5 0 Fifth generatio...

Page 32: ...onnector SAS PORT Rear 2SFF SAS SATA drive backplane The PCA BP 2SFF 2U G6 2SFF SAS SATA drive backplane is installed at the server rear to support two 2 5 inch SAS SATA drives Figure 39 2SFF SAS SATA...

Page 33: ...FF SAS SATA drive backplane The PCA BP 4SFF 2U G6 4SFF SAS SATA drive backplane is installed at the server rear to support four 2 5 inch SAS SATA drives Figure 41 4SFF SAS SATA drive backplane 1 x4 Mi...

Page 34: ...BP 2UniBay OCP 2U G6 2SFF UniBay drive backplane is installed together with an OCP adapter at the server rear to support two 2 5 inch SAS SATA NVMe drives Figure 43 2SFF UniBay drive backplane 1 SlimS...

Page 35: ...1 slot 3 6 3 GPU module power connector 4 PCIe5 0 x16 16 8 4 2 1 slot 1 4 PCIe5 0 x16 16 8 4 2 1 description PCIe5 0 Fifth generation signal speed x16 Connector bandwidth 16 8 4 2 1 Compatible bus ba...

Page 36: ...onnector 2 C 6 MCIO connector 2 A 7 MCIO connector 1 A 8 MCIO connector 1 C PCIe5 0 x16 16 8 4 2 1 description PCIe5 0 Fifth generation signal speed x16 Connector bandwidth 16 8 4 2 1 Compatible bus b...

Page 37: ...speed x16 Connector bandwidth 16 8 4 2 1 Compatible bus bandwidth including x16 x8 x4 x2 and x1 NOTE slot 1 4 When the riser card is installed in PCIe riser card slot 1 this slot corresponds to PCIe...

Page 38: ...4 2 1 description PCIe5 0 Fifth generation signal speed x16 Connector bandwidth 16 8 4 2 1 Compatible bus bandwidth including x16 x8 x4 x2 and x1 RC FHHL 2U G6 Figure 48 RC FHHL 2U G6 1 PCIe5 0 x16 16...

Page 39: ...in PCIe riser card slot 2 this slot corresponds to PCIe slot 6 This rule applies to all the other PCIe riser card slots For information about PCIe slots see Rear panel view RC 1FHFL R3 2U G6 Figure 4...

Page 40: ...PCIe5 0 x16 8 4 2 1 slot 7 PCIe5 0 x16 8 4 2 1 description PCIe5 0 Fifth generation signal speed x16 Connector bandwidth 8 4 2 1 Compatible bus bandwidth including x8 x4 x2 and x1 NOTE This type is ri...

Page 41: ...or PCIe5 0 x16 8 4 2 1 description PCIe5 0 Fifth generation signal speed x16 Connector bandwidth 8 4 2 1 Compatible bus bandwidth including x8 x4 x2 and x1 NOTE This type is riser card is not supporte...

Page 42: ...cluding x8 x4 x2 and x1 RC 5HHHL R5 2U G5 Figure 53 RC 5HHHL R5 2U G5 1 PCIe5 0 x16 8 4 2 1 slot 12 2 MCIO connector 2 3 PCIe5 0 x16 8 4 2 1 slot 13 4 MCIO connector 3 5 PCIe5 0 x16 8 4 2 1 slot 14 6...

Page 43: ...ot 12 4 PCIe5 0 x16 8 4 2 1 slot 11 5 GPU module power connector 6 GPU module power connector PCIe5 0 x16 8 4 2 1 description PCIe5 0 Fifth generation signal speed x16 Connector bandwidth 8 4 2 1 Comp...

Page 44: ...5 0 x16 16 8 4 2 1 description PCIe5 0 Fifth generation signal speed x16 Connector bandwidth 16 8 4 2 1 Compatible bus bandwidth including x16 x8 x4 x2 and x1 OCP adapter Figure 57 OCP adapter 1 MCIO...

Page 45: ...ation about the LCD smart management module connector on the system board see System board 3 LCD module shell Protects and secures the LCD screen 4 LCD screen Displays basic server information operati...

Page 46: ...U modules and OCP 3 0 adapters at the server rear The PCIe slot numbers vary by configuration Figure 60 PCIe slot numbering when riser cards are installed at the server rear Figure 61 PCIe slot number...

Page 47: ...log UEFI shell Execute the pci command For information about how to execute the command execute the help pci command Operating system The obtaining method varies by OS For Linux execute the lspci com...

Page 48: ...on measures prior to operation Processor model suffixes If the model of a processor is UN CPU INTEL 8490H the model suffix is H For more information about the supported processor models use the compon...

Page 49: ...drives that do not contain RAID information NVMe drives The server supports U 2 and E1 S NVMe drives Support for hot removal and managed hot removal of NVMe drives varies by operating system For more...

Page 50: ...onnector 2 SATA M 2 SSD card slot 1 Figure 65 SATA M 2 expander module rear view 1 SATA M 2 SSD card slot 2 NVMe M 2 SSDs An NVMe M 2 expander module is required for NVMe M 2 SSDs and you can install...

Page 51: ...1 2 NVMe M 2 SSD card slot 2 Server management module The server management module is installed on the system board to provide I O connectors and HDM out of band features for the server Figure 67 Ser...

Page 52: ...s two SD slots and forms RAID 1 by default To avoid the waste of SD card storage space install two SD cards that have the same storage capacity Figure 68 Serial DSD module Table 19 Component descripti...

Page 53: ...is required The description for PCIe5 0 x16 8 4 2 1 is as follows PCIe5 0 Fifth generation signal speed x16 Connector bandwidth 8 4 2 1 Compatible bus bandwidth including x8 x4 x2 and x1 For an x8 MC...

Page 54: ...the system board providing an x16 PCIe link for slot 4 with x8 MCIO connector SLOT 1 A N A Proce ssor 2 SLOT 2 A x8 MCIO connector Connected to MCIO connector C2 P2A on the system board providing an...

Page 55: ...PCIe5 0 x16 8 4 2 1 FHHL 75 W Proce ssor 2 SLOT 1 A x8 MCIO connector Connected to MCIO connector C2 P2A providing an x16 PCIe link for slot 4 with x8 MCIO connector SLOT 1 C N A Proce ssor 2 SLOT 1...

Page 56: ...sor 2 Table 24 Riser card and PCIe module compatibility 5 Riser card model Riser card location Slot or connector on the riser card PCIe slot or connector description PCIe module for PCIe slot or conne...

Page 57: ...o MCIO connector C1 P3A on the system board providing an x8 PCIe link for slot 13 N A Proce ssor 1 MCIO connector 4 x8 MCIO connector Connected to MCIO connector C2 P4A on the system board providing a...

Page 58: ...vels 0 1 5 10 Built in cache memory N A Built in flash N A Powerfail safeguard module Not supported Firmware upgrade Upgrade with the BIOS Standard storage controllers For more information use the com...

Page 59: ...MC or LSI For information about the available storage controllers and their vendors use the component compatibility lookup tool at http www h3c com en home qr default htm id 66 If the drives are insta...

Page 60: ...n about riser card and PCIe module compatibility see Riser card and PCIe module compatibility GPU modules For information about configuration guides for the power cords of GPU modules contact Technica...

Page 61: ...nd 6 5 Slots 2 3 4 5 and 6 6 Slots 1 2 3 4 5 and 6 7 Slots 1 2 3 4 5 6 and 7 8 Slots 1 2 3 4 5 6 7 and 8 9 Slots 1 2 3 4 5 6 7 8 and 9 10 Slots 1 2 3 4 5 6 7 8 9 and 10 14 Slots 1 2 3 4 5 6 7 8 9 10 1...

Page 62: ...fan module When any of the following conditions are met you must install the FAN 8056 2U G6 fan module The 12LFF drive backplane 25SFF drive backplane two 8SFF UniBay drive backplanes or three 8SFF U...

Page 63: ...6 NVMe U 2 drive slots up to 32 E1 S slots and up to 36 E3 S drive slots1 Optional SATA NVMe M 2 SSDs and serial DSD module Network 1 embedded 1 Gbps dedicated management port Up to two embedded OCP 3...

Page 64: ...4 848 mm 3 44 17 54 33 39 in Max weight 46 5 kg 102 51 lb NOTE 1 indicates a planned product specification For information about the current available configuration see the detailed product manuals O...

Page 65: ...om DIMMs About DIMMs The server supports DDR5 DIMMs DDR5 DIMMs can perform parity check on addresses and the DDR5 DIMMs cannot protect data from getting lost in case of unexpected system power outage...

Page 66: ...RDIMM Guidelines Only DDR5 DIMMs are supported IMPORTANT If liquid cooled modules are installed you must install two processors The server provides eight DIMM channels per processor and each channel h...

Page 67: ...actice install DDR5 DIMMs that have the same product code and DIMM specification type capacity rank and frequency For information about DIMM product codes use the component compatibility lookup tool a...

Page 68: ...hard drives NOTE An SFF Small Form Factor drive is a 2 5 inch drive An LFF Large Form Factor drive is a 3 5 inch drive Number of DIMMs Remarks D0 D1 C0 C1 B0 B1 A0 A1 E1 E0 F1 F0 G1 G0 H1 H0 0DIMMs Fo...

Page 69: ...of PCIe extended modules You can choose devices based on required module types and rates FC HBA modules Network adapters SSD expander modules For information about the system components that are avai...

Page 70: ...7 0 U3 64 bit VMware ESXi 8 0 64 bit For more information about the supported operating systems use the OS compatibility lookup tool at http www h3c com en home qr default htm id 65 For more informat...

Page 71: ...ators In addition FIST SMS supports transferring HDM event logs and updating server firmware and driver versions iFIST Integrated Fast Intelligent Scalable Toolkit an embedded server deployment tool f...

Page 72: ...ion management FIST provides the following advantages Focuses on the centralized intelligent management of H3C proprietary servers and supports three installation methods including the no installation...

Page 73: ...purchase consulting service and policy consulting and complaint and suggestion platforms Remote technical support After receiving the network or system failure report H3C engineers analyze and deal wi...

Page 74: ...2 01 America FCC FCC Part 15 Subpart B CLASS A Canada NTRL UL CSA C22 2 NO 62368 1 14 2nd Ed Issue Date 2014 12 01 Canada ISED ICES 003 CLASS A China RoHS GB T26572 2011 SJ T11364 2014 Europe RoHS 201...