1
Item
Specifications
•
(Optional.) Supports U-Center data center management platform
Security
Supports chassis intrusion detection, TCM/TPM module, two-factor authentication, and
Intel PFR 3.0 and SGX 2.0
Power and
heat
dissipation
•
(Optional.) Platinum
550W/800W/850W/1200W/1300W/1600W/2000W2400W/2700W power supplies,
supporting 1 + 1 redundancy
•
(Optional.) -48VDC/336VDC 800W power supplies, supporting 1 + 1 redundancy
•
(Optional.) Titanium CQC31-461288 certified grade V power supplies
•
Support hot-swappable redundant fans
Dimensions
(H × W × D)
2U chassis
•
Without a security bezel:
LFF&SFF models: 87.5 × 445.4 × 780 mm (3.44 × 17.54 × 30.71 in)
E1.S model: 87.5 × 445.4 × 820 mm (3.44 × 17.54 × 32.28 in)
•
With a security bezel:
LFF&SFF models: 87.5 × 445.4 × 808 mm (3.44 × 17.54 × 31.81 in)
E1.S model: 87.5 × 445.4 × 848 mm (3.44 × 17.54 × 33.39 in)
Max. weight
46.5 kg (102.51 lb)
NOTE:
[1] indicates a planned product specification. For information about the current available
configuration, see the detailed product manuals.
Operating environment requirements
Item
Specifications
Operating temperature
5 °C to 45 °C (41 °F to 113 °F), complying with ASHRAE class A4
The operating temperature range varies by server model and
configuration. For more information, see the detailed technical documents
for the server.
Storage temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Operating altitude
–60 m to +3000 m (–196.85 ft to +9842.52 ft)
The allowed maximum temperature decreases by 0.33 °C (32.59 °F) as the
altitude increases by 100 m (328.08 ft) from 900 m (2952.76 ft)
Storage altitude
–60 m to +5000 m (–196.85 ft to +16404.20 ft)
In a rack stacking environment, the maximum temperature might decrease because the cooling
conditions are related with power density within racks and heat dissipation capacity of racks.