11-13
Model
Vendor
Form
factor
Capacity
Interface
Rate
Link
width
SSD-1.6T-NVME-PM1725b
Samsung
HHHL
1.6 TB
PCIe
8 Gbps
×8
SSD-1.6T-NVME-PM1725b-M Samsung
HHHL
1.6 TB
PCIe
8 Gbps
×8
SSD-1.6T-NVME-PB516
Memblaze
HHHL
1.6 TB
PCIe
8 Gbps
×8
SSD-NVME-3.2T-EM-2
SHANNON
LP
3.2 TB
PCIe
8 Gbps
×8
SSD-NVME-2T-EV
Memblaze
LP
2.0 TB
PCIe
8 Gbps
×8
SSD-NVME-2T-P4600
Intel
HHHL
2.0 TB
PCIe
8 Gbps
×8
SSD-NVME-3.2T-PBlaze5
Memblaze
HHHL
3.2 TB
PCIe
8 Gbps
×8
SSD-NVME-4T-PBlaze5
Memblaze
HHHL
4.0 TB
PCIe
8 Gbps
×8
SSD-NVME-4T-P4500
Intel
HHHL
4.0 TB
PCIe
8 Gbps
×4
SSD-NVME-4T-P4600
Intel
HHHL
4.0 TB
PCIe
8 Gbps
×8
SSD-NVME-6.4T-PBlaze5
Memblaze
HHHL
6.4 TB
PCIe
8 Gbps
×8
Drive LEDs
The server supports SAS, SATA, and NVMe drives, of which SAS and SATA drives are hot
swappable by default. You can use the LEDs on a drive to identify its status after it is connected to a
storage controller.
shows the location of the LEDs on a drive.
Figure 11-2 Drive LEDs
(1) Fault/UID LED
(2) Present/Active LED
To identify the status of a SAS or SATA drive, use
. To identify the status of an NVMe drive,
use
.
Table 11-4 SAS/SATA drive LED description
Fault/UID LED status
Present/Active LED status
Description
Flashing amber (0.5 Hz)
Steady green/Flashing green
(4.0 Hz)
A drive failure is predicted. As a best
practice, replace the drive before it fails.
Steady amber
Steady green/Flashing green
(4.0 Hz)
The drive is faulty. Replace the drive
immediately.
Steady blue
Steady green/Flashing green
(4.0 Hz)
The drive is operating correctly and is
selected by the RAID controller.
Off
Flashing green (4.0 Hz)
The drive is performing a RAID migration or
rebuilding, or the system is reading or
writing data to the drive.