62
Field Remarks
Transceiver info checksum error
Transceiver information checksum error
Transceiver type and port configuration mismatch
Transceiver type does not match port configuration.
Transceiver type not supported by port hardware
Transceiver type is not supported on the port.
XFP
RX loss of signal
RX signal is lost.
RX not ready
RX is not ready
RX CDR loss of lock
RX clock cannot be recovered.
TX fault
TX fault.
TX not ready
TX is not ready.
TX CDR loss of lock
TX clock cannot be recovered.
Module not ready
Module is not ready.
APD supply fault
Avalanche Photo Diode (APD) supply fault
TEC fault
Thermoelectric Cooler (TEC) fault.
Wavelength unlocked
Wavelength of optical signal exceeds the
manufacturer's tolerance.
RX power high
RX power is high.
RX power low
RX power is low.
TX power high
TX power is high.
TX power low
TX power is low.
TX bias high
TX bias current is high.
TX bias low
TX bias current is low.
Temp high
Temperature is high.
Temp low
Temperature is low.
Voltage high
Voltage is high.
Voltage low
Voltage is low.
Transceiver info I/O error
Transceiver information read and write error.
Transceiver info checksum error
Transceiver information checksum error.
Transceiver type and port configuration mismatch
Transceiver type does not match port configuration.
Transceiver type not supported by port hardware
Transceiver type is not supported on the port.
# Display the currently measured values of the fault detection parameters of the transceiver module
plugged in interface GigabitEthernet 3/1/1.
<Sysname> display transceiver diagnosis interface Gigabitethernet 3/1/1
GigabitEthernet3/1/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
36 3.31 6.13 -35.64 -5.19