Configuration page
Configuring Common Settings for Modem Login (Optional)
Follow these steps to configure common settings for modem login:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable display of copyright
information
copyright-info
enable
Optional
Enabled by default.
Enter one or more AUX user
interface views
user-interface aux first
-
number
[
last-number
]
—
Configure the
baud rate
speed
speed-value
Optional
By default ,the baud rate is 9600
bps.
Transmission rate is the number of
bits that the device transmits to the
terminal per second.
Configure the
parity check mode
parity
{
even
|
mark
|
none
|
odd
|
space
}
Optional
By default, the parity check mode of
the AUX port is set to
none
, which
means no check bit.
Configure
AUX port
properties
Configure the stop
bits
stopbits
{
1
|
1.5
|
2
}
Optional
By default, the stop bits of the
console port is 1.
Stop bits are the last bits transmitted
in data transmission to unequivocally
indicate the end of a character. The
more the bits are, the slower the
transmission is.