background image

Manual Version: 6PW102-20170414 

BOM: 3123A0R4

 

iv 

3.

 

Place the card horizontally with the surface-mounted components facing upward. Pull outward the 
ejector levers and gently push the card in along the slot guide rails until the card is in close contact 

with the backplane. (See callout 1 in 

Figure 3 

.) 

4.

 

Push the ejector levers inward. (See callout 2 in 

Figure 3 

.) 

5.

 

Tighten the captive screws with a Phillips screwdriver to secure the card in the slot. (See callout 3 
in 

Figure 3 

.) 

Figure 3 Installing the NSQ1SUPB0 

 

(1) Gently push the card in along the slot guide rails until the card is in close contact with the backplane. 
(2) Push the ejector levers inward. 
(3) Tighten the captive screws with a Phillips screwdriver, and installation is finished. 

 

4.2 

 

Removing the NSQ1SUPB0 

1.

 

Use a Phillips screwdriver to loosen the captive screws at both sides of the card until all pressure 

is released. 

2.

 

Pull the ejector levers at both sides of the card outward, and pull the card along the guide rails until 
it completely comes out of the backplane. 

3.

 

Place the card on an anti-static workbench with the surface-mounted components up, or put it in an 
anti-static bag. 
If no new card is to be installed, install a filler panel to prevent dust and ensure good ventilation in 

the device. 

 

Software upgrade 

For more information, see the release notes. 

 

Obtaining documentation 

To access the most up-to-date H3C product documentation on the H3C websit1.

 

Go to

2.

 

Choose the desired product category and model. 

 
Copyright © 2017 New H3C Technologies Co., Ltd. 

Summary of Contents for SecPath M9000 NSQ1SUPB0 MPU

Page 1: ...Ethernet port LED 4 Fan status LED 5 Card status LED 6 MPU status LED ACTIVE 7 Reset button Table 1 Card specifications Item Specification Dimensions H W D 40 399 352 mm 1 57 15 71 13 86 in Power consumption 45 W to 50 W Weight 2 97 kg 6 55 lb Hot swapping Supported Connector type RJ 45 Interfaces 1 console port One 10 100 1000BASE T Ethernet port Ambient temperature Operating 0 C to 45 C 32 F to ...

Page 2: ...9 21 ft Services Provides connection to an ASCII terminal Provides connection to the serial port of a local or remote through a pair of modems PC running terminal emulation program Supports command line interface CLI Table 3 10 100 1000BASE T copper port specifications Item Specification Connector RJ 45 Interface standard 802 3 802 3u and 802 3ab Interface type MDI MDIX autosensing Supported cable...

Page 3: ...OTE A quick flashing RUN LED indicates that the card is starting up rather than operating properly It is normal that the ALM LED for an LPU lights for a period of time at the initial phase of the system startup Table 7 MPU ACTIVE LED description LED status Description On The MPU is active Off The MPU is in standby status The MPU is faulty Examine the card LED for an MPU problem 4 Installing and re...

Page 4: ...ips screwdriver and installation is finished 4 2 Removing the NSQ1SUPB0 1 Use a Phillips screwdriver to loosen the captive screws at both sides of the card until all pressure is released 2 Pull the ejector levers at both sides of the card outward and pull the card along the guide rails until it completely comes out of the backplane 3 Place the card on an anti static workbench with the surface moun...