Table 18 Switching fabric module specifications
Model Item Specifications
•
LSVM1SRPC1
•
LSVM1SRPA1
Interfaces
•
1 console port
•
1 × 10/100/1000Base-T port for management and upgrade
•
1 USB port (USB 2.0, Host)
Transmission rate
•
Console port: 9600 bps (default) to 115200 bps
•
10/100/1000Base-T port: 10/100/1000 Mbps
Transmission
medium and max
transmission
distance
•
Console port: 15 m (49.21 ft) over asynchronous serial
cable
•
10/100/1000Base-T port: 100 m (328.08 ft) over category-5
twisted pair cable
Power modules
The PSR1800-56A and PSR1800-56D power modules are available for the switch. The
PSR1800-56A is an AC/DC-input and DC-output power module that provides a maximum output of
1800 W. The PSR1800-56D is a DC-input and DC-output power module that provides a maximum
output of 1800 W.
The S9804 switch supports 1+1 power redundancy. The S9810 switch supports N+1 or N+N power
redundancy. N can be 1 or 2. The number of power modules that a switch requires is determined by
the power supply mode and system power consumption. Make sure the total maximum output power
of the installed power modules is greater than the system power consumption. H3C recommends
that you reserve 20% of the maximum output power.
describe PSR1800-56A and PSR1800-56D power module specifications,
respectively.
Table 19 PSR1800-56A power module specifications
Item Specification
Rated input voltage range
•
100 VAC to 240 VAC @ 50 Hz or 60 Hz (AC input)
•
240 VDC (high voltage DC input)
Maximum input current
•
13 A (AC input)
•
10.5 A (high voltage DC input)
Output voltage
–56 VDC
Output current
•
32.2 A (201 VAC to 240 VAC input voltage)
•
19.6 A (100 VAC to 200 VAC input voltage)
•
32.2 A (240 VDC input voltage)
Maximum output power
•
1800 W (201 VAC to 240 VAC input voltage)
•
1100 W (100 VAC to 200 VAC input voltage)
•
1800 W (240 VDC input voltage)
Operating temperature
–10°C to +55°C (14°F to 131°F)
Relative humidity
5% to 95%
NOTE:
You can install one power module if the input voltage is in the range of 200 VAC to 240 VAC. You