background image

Manual version: 6PW102-20141219 

BOM: 3123A13M

 

ii 

Table 1 Card specifications 

Item Specification 

CF card 

One CF card slot, 256MB by default for the external CF card  
256 MB, 512 MB, or 1 GB for an optional external CF card 

Dimensions (H × W × D) 

40.1 × 400 × 380 mm (1.58 × 15.74 × 14.96 in) 

Hot swapping 

Supported 

Ports 

 

1 console port 

 

2 USB ports (reserved for future use) 

 

2 pairs of combo ports, each pair containing the following ports:  

{

 

1 x 10/100/1000BASE-T copper port 

{

 

1 x 1000BASE-X SFP fiber port 

You can use the 

combo

 

enable

 { 

copper

 | 

fiber 

} command to activate either of 

the ports in a pair. By default, the copper combo port is activated. 

Ambient temperature 

 

Operating: 0°C to 45°C (32°F to 113°F) 

 

Not operating: –40°C to +70°C (–40°F to +158°F) 

Ambient relative humidity 

 

Operating: 10% to 95%, noncondensing 

 

Non-operating: 5% to 95%, noncondensing 

Compatible device models 

H3C S9500 series switches 

System software version 

See the release notes that come with the card. 

 

Table 2 Console port specifications 

Item Specification 

Connector RJ-45 

Interface standard 

RS-232 

Transmission baud rate 

9600 bps (default) to 115200 bps 

Transmission medium 

Asynchronous serial cable 

Transmission distance 

15 m (49.21 ft) 

Services 

 

Provides connection to an ASCII terminal. 

 

Provides connection to the serial port of a local or remote PC (through a 

pair of modems) that is running a terminal emulation program. 

 

Supports command line interface (CLI). 

 

Table 3 10/100/1000BASE-T copper port specifications 

Item Specification 

Connector RJ-45 

Interface standard 

802.3, 802.3u, and 802.3ab 

Interface type 

MDI/MDIX autosensing 

Supported cable 

Category-5 (or above) twisted pair cable 

Transmission distance 

100 m (328.08 ft) 

Summary of Contents for S9500 LSB1LB1A0

Page 1: ...D 3 CF LED CFS 4 Console port CONSOLE 5 USB interface 1 reserved 6 USB interface 2 reserved 7 Management Ethernet interface 1 10 100 1000BASE T 8 Management Ethernet interface 2 10 100 1000BASE T 9 Management Ethernet interface 1 LED LINK 10 Management Ethernet interface 1 LED ACT 11 Management Ethernet interface 2 LED LINK 12 Management Ethernet interface 2 LED ACT 13 Management interface 3 Elect...

Page 2: ... relative humidity Operating 10 to 95 noncondensing Non operating 5 to 95 noncondensing Compatible device models H3C S9500 series switches System software version See the release notes that come with the card Table 2 Console port specifications Item Specification Connector RJ 45 Interface standard RS 232 Transmission baud rate 9600 bps default to 115200 bps Transmission medium Asynchronous serial ...

Page 3: ...E LX SM1310 A 1310 nm LC 9 125 μm single mode optical fiber 10 km 6 21 miles SFP GE LH40 SM1310 1310 nm LC 9 125 μm single mode optical fiber 40 km 24 86 miles SFP GE LH40 SM1550 1550 nm LC 9 125 μm single mode optical fiber 40 km 24 86 miles SFP GE LH70 SM1550 1550 nm LC 9 125 μm single mode optical fiber 70 km 43 5 miles SFP GE LH100 SM1550 1550 nm LC 9 125 μm single mode optical fiber 100 km 62...

Page 4: ... Do not touch the components on the PCB 5 1 Installing the card 1 Locate the slot where you will install the LSB1LB1A0 and remove the blank panel from the position This manual describes installing the LSB1LB1A0 to slot 2 2 Push the module with the components facing upward into the slot along the guide rails until the positioning hole of the module is seated onto the positioning pin on the backplan...

Page 5: ...ation about other login methods see H3C SecBlade LB Module Configuration Guides To log in to the card from the switch s CLI perform the following task in user view Task Command Remarks Log in to the card through OAP In standalone mode oap connect slot slot number In IRF mode oap connect chassis chassis number slot slot number To return to the CLI interface of the switch press Ctrl K 7 Software upg...