8
b.
Verify that the power module is in an acceptable temperature range. Dust buildup might
cause high temperature. If dust is accumulated on the power module, remove the dust.
Then remove and reinstall the power module. Execute the
display power
command to
verify that the power module has changed to
Normal
state. If the power module remains in
Fault
state, go to step
c.
Install the power module into an empty power module slot. Then execute the
display
power
command to verify that the power module has changed to
Normal
state in the new
slot. If the power module remains in
Fault
state, replace the power module.
4.
If the issue persists, contact H3C Support.
Newly installed power module failure
Symptom
A newly installed power module has failed.
Troubleshooting flowchart
Figure 3 Troubleshooting newly installed power module failure
Solution
To resolve the issue:
1.
Identify the operating state of the power module.
<Sysname> display power
Slot 1:
PowerID State Mode Current(A) Voltage(V) Power(W)
1 Normal AC -- -- --
2 Absent -- -- -- --
If the power module is in
Absent
state, go to step
. If the power module is in
Fault
state, go to
.