1-3
z
Spare cables modes: PSE uses the twisted pairs (4, 5, 7 and 8) of category-3/5 cables, which are
spare during data transmission, to power the PD.
S5500-SI series switches only support for signal mode.
Configuring a PoE Interface through the Command Line
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter PoE interface view
interface interface-type
interface-number
—
Enable PoE
poe enable
Required
Disabled by default.
Configure the maximum power
for the PoE interface
poe max-power
max-power
Optional
15,400 milliwatts by default.
Configure the PoE mode for the
PoE interface
poe mode
signal
Optional
signal
(power over signal
cables) by default.
Configure a description for the
PD connected to the PoE
interface
poe pd-description
string
Optional
By default, no description for
the PD connected to the PoE
interface is available.
Configuring PoE Interfaces Through a PoE Configuration File
A PoE configuration file is used to configure at the same time multiple PoE interfaces with the same
attributes to simplify operations. This configuration method is a supplement to the command line
configuration.
The PoE configuration file features:
z
You can create multiple PoE configuration files for different user group and apply the specific PoE
configuration file to the port a user group uses.
z
When you use a PD on a port with PoE configuration file being applied, the configuration in the PoE
configuration file will be enabled.
Commands in a PoE configuration file are called configurations.
Summary of Contents for S5500-SI Series
Page 161: ...3 10 GigabitEthernet1 0 1 2 MANUAL...
Page 220: ...1 7 Clearing ARP entries from the ARP table may cause communication failures...
Page 331: ...1 7 1 1 ms 1 ms 1 ms 1 1 6 1 2 1 ms 1 ms 1 ms 1 1 4 1 3 1 ms 1 ms 1 ms 1 1 2 2 Trace complete...
Page 493: ...2 8...
Page 1111: ...1 10 Installing patches Installation completed and patches will continue to run after reboot...