2-8
Chassis
Installation
methods
Installation requirements
Installation
procedure
S5560S-28S-EI
S5560S-52S-EI
S5130S-28S-HI
S5130S-52S-HI
S5130S-28C-HI
S5130S-52C-HI
S5560S-28S-PWR-
EI
S5560S-52S-PWR-
EI
S5130S-28S-PWR-
HI
S5130S-28S-UPW
R-HI
S5130S-52S-PWR-
HI
S5130S-28C-PWR-
HI
S5130S-52C-PWR-
HI
Using front and
rear mounting
brackets
•
Install the front mounting brackets at
the port side or power module side.
•
Install the rear mounting brackets
according to the rack depth.
If the rack depth is in the range of
429 to 595 mm (16.89 to 23.43 in),
orient the bracket with the wide
flange inside the rack.
If the rack depth is in the range of
274 to 440 mm (10.79 to 17.32 in)
and the distance from the rear rack
posts to the inner surface of the
cabinet door is longer than 153 mm
(6.02 in), orient the bracket with the
wide flange outside the rack.
•
To use PSR1110-56A power modules,
do not install the switch in a rack with a
depth of 600 mm (23.62 in)
See
"
switch by using front
and rear mounting
brackets
Figure 2-2 Procedure for rack-mounting the switch by using the front mounting brackets
Figure 2-3 Procedure for rack-mounting the switch by using the front and rear mounting
brackets
NOTE:
If a rack shelf is available, you can put the switch on the rack shelf, slide the switch to an appropriate
location, and attach the switch to the rack by using the mounting brackets.
Attach the front
mounting brackets to the
two sides of the switch
Identify the mounting position (port
side or power side) for the
mounting brackets
Mount the switch in the rack
Attach the front
mounting
brackets to the
two sides of the
switch
Attach the load
bearing screws to
the switch
Attach the
rear
mounting
brackets to
rack posts
Identify the mounting
position (port side or
power side) for the
mounting brackets
Mount the switch in
the rack