15
Connecting a power cord for the built-in DC power module
(S5130-28PS-EI switch)
CAUTION:
The S5130-28PS-EI switch has a built-in DC power module with an RPS receptacle exposed
externally.
•
You can use only a RPS800-A power module to supply power to the DC power module.
•
No DC power cord is provided with the switch. You can use only a DC power cord with an H2*7
connector and compatible with the RPS800-A power module for the DC power module.
To connect a power cord for the built-in DC power module on an S5130-28PS-EI switch:
1.
Remove the screws on the RPS receptacle cover and then remove the cover, as shown
in
Keep the removed cover secure. Reinstall the cover if you will not use the RPS receptacle.
2.
Correctly orient the RPS power cord connector and insert the connector into the RPS
receptacle on the switch. See callout 1 in
.
The RPS receptacle and RPS power cord connector have disorientation rejection designs. If
you cannot insert the connector into the receptacle, re-orient the connector rather than use
excessive force to push it in.
3.
Use a flat-blade screwdriver to fasten the screws on the connector to secure the connector to
the receptacle. See callout 2 in
.
4.
Connect the other end of the power cord to a RPS800-A power module.
Figure 21 Connecting a power cord for the built-in power module on an S5130-28PS-EI
switch (1)