3-10
Figure 3-8 Removing the filler panel from a fabric module slot (S12516R)
(1) Loosen the captive screws on the ejector levers
(2) Rotate the ejector levers outward
(3) Pull the filler panel out of the slot along the guide rails
Installing fan trays
WARNING!
•
When you hot swap a fan tray, ensure electricity safety.
•
When you hot swap a fan tray, only one fan tray is operating and it automatically increases the
fan rotation speed and makes louder noise. Take protection measures such as wearing an
earmuff or earplug. In addition, make good preparation before the hot swapping to minimize the
operation time.
IMPORTANT:
•
Fan trays cover fabric module slots. Before you install a fan tray, install fabric modules or filler
panels in the fabric module slots that will be covered by the fan tray.
•
Replace a fan tray only when the other fan tray is operating correctly.
•
To prevent dust from entering the chassis, keep the failed fan tray in position before the
replacement.
The device has two fan tray slots: FAN1 and FAN2. One fan tray is sufficient for heat dissipation of
the device. As a best practice, install two fan trays on the device for redundancy and noise
reduction.
1
1
2
3
2