15
Installing an air filter (optional)
Air filters of the S10500 Switch Series are optional. If you have ordered air filters, install the air filters
before mounting the switch to the rack.
•
S10508-V
—The air filter is located at the air intake of the front of the switch. For the installation
procedures, see
S10508-V Air Filter User Manual
. Before installing an air filter, install the power
cable management brackets to the chassis.
•
Other models
—The air filter is located at the left of the chassis. For the installation procedures, see
S10504 Air Filter User Manual, S10508 Air Filter User Manual
, and
S10512 Air Filter User
Manual
.
Mounting the switch to the rack
CAUTION:
•
Do not hold the handle of the fan tray, power module, or the back cover of the chassis, or the air vents
of chassis. Any attempt to carry the switch with these parts might cause equipment damage or even
bodily injury.
•
After placing the switch on the slide rails, do not leave go of your hands immediately because this might
tip the switch, damaging the switch or even causing bodily injury.
To mount the switch to the rack:
1.
Move the chassis to face the rear of the chassis towards the front of the rack.
2.
Use at least two people to lift the switch by using the handles or supporting the bottom of the
chassis until the bottom of the switch is a little higher than the slide rails on the rack.
H3C recommends using a mechanical lift for moving your switch.
3.
Place the switch on the slide rails and slide the switch along the slide rails until the mounting
brackets on the switch touch the front rack posts, as shown in callout 1 on
.
4.