H3C PSR600-54A-B Installation Manual Download Page 32

 

2-22 

Figure2-29 Removing a power supply 

 

 

Removing a PSR450-12D power supply 

1. 

Wear an ESD wrist strap. Make sure the strap makes good skin contact and is reliably 
grounded. 

2. 

Remove the power cord from the power supply. As shown in 

Table3-3

, use a flathead 

screwdriver to loosen the two screws on the power cord connector and then pull the connector 
out. 

3. 

Holding the power supply handle with one hand and using your thumb to press the latch on the 
power supply rightwards, pull the power supply part way out of the slot. Supporting the power 
supply bottom with the other, pull the power supply slowly out of the slot. 

1

2

Summary of Contents for PSR600-54A-B

Page 1: ...PSR250 12A1 PSR450 12D PSR1600 54A B PSR920 54A B or PSR600 54A B power supply 2 19 Installing a PSR180 12A F or PSR180 12A B power supply 2 20 Removing a PSR250 12A PSR250 12A1 PSR1600 54A B PSR920...

Page 2: ...g IRF topology and connections 4 3 Identifying physical IRF ports on the member switches 4 4 Planning the cabling scheme 4 6 Configuring basic IRF settings 4 9 Connecting the physical IRF ports 4 9 Ve...

Page 3: ...th or liquid Do not place the switch near water or in a damp environment Prevent water or moisture from entering the switch chassis Do not place the switch on an unstable case or desk The switch might...

Page 4: ...ting high relative humidity can cause poor insulation electricity leakage mechanical property change of materials and metal corrosion Lasting low relative humidity can cause washer contraction and ESD...

Page 5: ...osive gas limit EMI If AC power is used use a single phase three wire power receptacle with protection earth PE to filter interference from the power grid Keep the device far away from radio transmitt...

Page 6: ...e the equipment room is not connected to sewer vertical shaft or septic tank pipelines and keep it far away from these pipelines The air inlet of the equipment room must be away from such pollution so...

Page 7: ...ors and direct ventilation cabinets near pollution sources houses without direct exposure to sunlight or rain railway station platforms stadiums uncleaned rooms after decoration and rooms under decora...

Page 8: ...system provides a DC distribution box prepare DC power cords yourself Do not use the power cord provided with the switch on other devices Laser safety WARNING The switch is a Class 1M laser device Di...

Page 9: ...ided All switch models N A Grounding cable The grounding cable in this figure is for illustration only Your grounding cable might be slightly different from this one 1 provided All switch models N A G...

Page 10: ...or illustration only Your power cord retainer clip might be slightly different from this one PSR180 12A B and PSR180 12A F power supplies 1 provided S6520X 30HF EI S6520X 54HF EI S6520X 30HF HI S6520X...

Page 11: ...ng the switch CAUTION Keep the tamper proof seal on a mounting screw on the chassis cover intact and if you want to open the chassis contact H3C for permission Otherwise H3C shall not be liable for an...

Page 12: ...tion Turn on the circuit breakers Operating correctly Turn off the circuit breakers Troubleshoot the switch No Yes End Connect interface cables Ground the switch Install fan trays Install power suppli...

Page 13: ...ckets as required near the power supply side or port side Install the rear mounting brackets based on the rack depth distance between the front and rear rack posts If the rack depth is in the range of...

Page 14: ...nd shoulder screws as shown in Figure2 5 S6520X 30QC EI S6520X 54QC EI S6520X 30QC HI S6520X 54QC HI S6520X 30HC EI S6520X 54HC EI S6520X 30HC HI S6520X 54HC HI Provided N A S6520X 54HC UP WR EI Provi...

Page 15: ...tion near the power supplies for the front mounting brackets Select one position as needed To attach the front mounting brackets to the chassis 1 Place the wide flange of the mounting bracket against...

Page 16: ...quires two people To mount the switch in the rack 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Verify that the front mounting brackets have been secure...

Page 17: ...example Rack mounting the switch by using front and rear mounting brackets Attaching the front mounting brackets and shoulder screws to the switch The switch provides two installation positions on it...

Page 18: ...Select one as required Figure2 10 Attaching the front mounting brackets and shoulder screws to the chassis Attaching the rear mounting brackets to the rack 1 Determine the switch installation positio...

Page 19: ...ng the rear mounting brackets to the rack with the wide flange outside the rack Mounting the switch in the rack 1 Wear an ESD wrist strap Make sure the strap makes good skin contact and is reliably gr...

Page 20: ...and pushes the chassis into the rack gently Make sure the shoulder screws rest firmly on the upper edge of the rear mounting brackets See Figure2 13 and Figure2 14 5 The other person attaches the fron...

Page 21: ...on Do not place heavy objects on the switch To mount the switch on a workbench 1 Verify that the workbench is sturdy and reliably grounded 2 Place the switch with bottom up and clean the round holes i...

Page 22: ...ower and data lines from damages Prevents electrical fires lightning strokes electromagnetic coupling interferences ESD damages and ensures correct operation of the power system Select a grounding met...

Page 23: ...nding cable to a grounding strip Use either of the following methods to connect the grounding cable to a grounding strip in the equipment room Method 1 a Use needle nose pliers to bend the bare metal...

Page 24: ...mmer a 2 5 m 8 20 ft or longer angle iron or steel tube into the earth ground to act as a grounding conductor Make sure a minimum of 0 7 m 2 30 ft is left between the top of the grounding conductor an...

Page 25: ...g strip and make sure the grounding resistance is less than 1 If you ground the switch by using a grounding conductor buried in the earth ground perform the following tasks a Use a multimeter to measu...

Page 26: ...the installation site The LSWM1FANSCE fan tray draws in cool air from the faceplate Its handle is blue The LSWM1FANSCBE fan tray expels hot air from the faceplate Its handle is red The LSPM1FANSA SN...

Page 27: ...ns the switch does not check the preferred airflow direction at system start You only need to ensure consistent airflow directions of all fan trays on the switch If the airflow directions of the fan t...

Page 28: ...al procedure CAUTION To prevent damage to the power supply and the connectors on the backplane insert the power supply gently If you encounter a hard resistance when inserting the power supply pull ou...

Page 29: ...er panel secure for future use Figure2 25 Removing the filler panel from the target power supply slot 3 Unpack the power supply Make sure the power supply model is as required Keep the packaging box a...

Page 30: ...el Figure2 27 Removing the filler panel 3 Unpack the power supply and verify that the power supply model is correct 4 Correctly orient the power supply with the power supply slot use the letters on th...

Page 31: ...n ESD wrist strap Make sure the strap makes good skin contact and is reliably grounded 2 Disconnect the power cord 3 Press the latch on the power supply towards the handle side and pull the power supp...

Page 32: ...r supply As shown in Table3 3 use a flathead screwdriver to loosen the two screws on the power cord connector and then pull the connector out 3 Holding the power supply handle with one hand and using...

Page 33: ...ower supply To remove a PSR180 12A B power supply 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Disconnect the power cord 3 Loosen the captive screws on...

Page 34: ...he power cord for a PSR250 12A1 power supply To connect the power cord for a PSR250 12A1 power supply 1 Wear an ESD wrist strap Make sure the strap makes good skin contact and is reliably grounded 2 P...

Page 35: ...rist strap and make sure it makes good skin contact and is reliably grounded 2 Attach the power cord retainer clip supplied with the power supply into the two holes next to the AC input power receptac...

Page 36: ...input receptacle on the power supply as shown by callout 1 in Figure2 35 If you orient the DC power cord connector upside down you cannot insert it into the DC power input receptacle 2 Use a flathead...

Page 37: ...id optical electrical switch main cable and pigtail of the powered device You must connect the main cable to the two pigtails on site Connecting a hybrid copper fiber cable 1 Use a utility knife to pe...

Page 38: ...terface modules can be hot swapped The S6520X 30QC EI S6520X 54QC EI S6520X 30HC EI S6520X 54HC EI S6520X 30QC HI S6520X 54QC HI S6520X 30HC HI and S6520X 54HC HI switches each provide two expansion s...

Page 39: ...lot method 1 Figure2 39 Removing the filler panel from the target expansion slot method 2 3 Unpack the expansion card 4 Optional If the expansion card has one ejector lever perform the following steps...

Page 40: ...the card as shown by callout 1 in Figure2 41 b Gently push the expansion card into the slot along the guide rails until the expansion card has good contact with the chassis as shown by callout 2 in F...

Page 41: ...ever perform the following steps to install it a Gently push the expansion card into the slot along the guide rails until the expansion card has good contact with the chassis See callout 1 in Figure2...

Page 42: ...ion card install a filler panel in the slot to prevent dust and ensure good ventilation in the switch Verifying the installation Before powering on the switch verify the following items There is enoug...

Page 43: ...s an example from the serial console port Figure3 1 Connecting the switch to a configuration terminal As shown in Table3 1 three types of console cables can be used for connecting the switch to a conf...

Page 44: ...C console cable DB9 to RJ45 console cable 04042967 USB to RJ45 console cable 0404A1EE Micro USB console cable User supplied Connecting a DB9 to RJ45 console cable CAUTION Follow these guidelines when...

Page 45: ...RJ45 console driver on the configuration terminal and then connect the USB to RJ45 console cable to the configuration terminal If you have connected a USB to RJ45 console cable to the configuration te...

Page 46: ...indows system of the configuration terminal supports the driver 3 If the Windows system supports the driver install PL23XX M_LogoDriver_Setup_v200_20190815 exe 4 Click Next on the welcome page of the...

Page 47: ...on terminal To connect to the PC through a micro USB console cable 1 Connect the standard USB Type A connector to the USB port of the PC 2 Connect the micro USB Type B connector to the micro USB conso...

Page 48: ...3 6 Figure3 5 Device Driver Installation Wizard 6 Click Continue Anyway if the following dialog box appears Figure3 6 Software Installation 7 Click Finish...

Page 49: ...about the terminal emulator programs see the user guides for these programs Configure the terminal parameters as follows Bits per second 9 600 Data bits 8 Parity None Stop bits 1 Flow control None St...

Page 50: ...u options differ with software versions For more information about Boot ROM menu options see the software matching release notes for the device After the startup process is completed you can access th...

Page 51: ...lowchart Figure4 1 IRF fabric setup flowchart To set up an IRF fabric Step Description 1 Plan IRF fabric setup Plan the installation site and IRF fabric setup parameters Planning IRF fabric size and t...

Page 52: ...l switching capacities of all member switches Plan the installation site depending on your network solution as follows Place all IRF member switches in one rack for centralized high density access Dis...

Page 53: ...you must bind a minimum of one physical port to it When connecting two neighboring IRF member switches you must connect the physical ports of IRF port 1 on one switch to the physical ports of IRF por...

Page 54: ...hernet ports 10G 5G 2 5G 1000BASE T autosensing Ethernet ports SFP ports QSFP ports Physical ports on interface modules and the front panel can be bound to the same IRF logical interface All physical...

Page 55: ...on the front panel 4 QSFP28 ports on the front panel The following ports provided on the expansion cards installed on the front panel 10G 5G 2 5G 1000 100BASE T autosensing Ethernet ports SFP ports Th...

Page 56: ...pecifications for the switch series SFP28 ports SFP28 transceiver modules and optical fibers or SFP28 cables For the available models see hardware information and specifications for the switch series...

Page 57: ...4 7 Figure4 4 Connecting the switches in one rack 1 2 3 4 5 6 7 8 9...

Page 58: ...4 8 Figure4 5 IRF fabric topology 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9...

Page 59: ...see the virtual technologies configuration guide in the configuration guides for the switch series Connecting the physical IRF ports Use twisted pair SFP QSFP SFP28 QSFP28 cables or SFP QSFP SFP28 QS...

Page 60: ...irf configuration Display IRF fabric topology information display irf topology NOTE To avoid IP address collision and network problems configure a minimum of one multi active detection MAD mechanism...

Page 61: ...switches The status LED on a power supply in combination with the power supply status LED on the switch indicates that the power supply has failed S6520X 30HF EI S6520X 54HF EI S6520X 30HF HI and S65...

Page 62: ...esolve the issue 1 Verify that the power supply is supplying power to the switch correctly 2 Verify that the console cable is correctly connected 3 Verify that the console cable does not have any issu...

Reviews: