Manual Version: 6PW104-20170414
BOM: 3123A0R3
iii
Figure 3 Installing an NSQ1FAB04B0
(1) Gently push the switching fabric module in along the slot guide rails until the switching fabric module is in
close contact with the backplane.
(2) Push the ejector levers inward.
(3) Tighten the captive screws with a Phillips screwdriver.
(4) Installation is finished
4.2
Removing the NSQ1FAB04B0
1.
Use a Phillips screwdriver to loosen the captive screws at both sides of the switching fabric module
until all pressure is released.
2.
Pull the ejector levers at both sides of the switching fabric module outward, and pull the switching
fabric module along the guide rails until it completely comes out of the backplane.
3.
Place the switching fabric module on an anti-static workbench with the surface-mounted
components up, or put it in an anti-static bag.
If no new switching fabric module is to be installed, install a filler panel to prevent dust and ensure
good ventilation in the device.
5
Obtaining documentation
To access the most up-to-date H3C product documentation on the H3C websit1.
Go to
Choose the desired product category and model.
Copyright © 2017 New H3C Technologies Co., Ltd.
1
3
2
4