ii 

Item Specification

Ambient humidity 

Operating: 10%RH to 95%RH, noncondensing 
Storage: 5%RH to 95%RH, noncondensing 

Compatible device model and slot 

M9006 gateway (slot 6 to slot 9) 
T9006 IPS (slot 6 to slot 9) 

 

 

LEDs 

The NSQ1FAB04B0 provides LEDs to show the operating status of the switching fabric module. 

Table 2 LED description 

RUN LED 

ALM LED 

Description

Flashing (0.5 Hz) 

Off 

The switching fabric module is operating properly.  

Off 

On 

The switching fabric module is faulty.  

Flashing (0.5 Hz) 

On 

The temperature of the switching fabric module has exceeded the 
upper or lower limit.  

Off 

Off 

The switching fabric module has not started.  

On 

Off 

The switching fabric module is up.  

 

 

Installing and removing the NSQ1FAB04B0 

 

 

CAUTION: 

 

Wear a well-grounded ESD-preventive wrist before you install or remove the switching fabric 
module. 

 

Do not touch the surface-mounted components directly with your hands when you install or remove
the switching fabric module. 

 

At least one switching fabric module is required. Install in to either Slot 6 or Slot 7. You can install a 
maximum of 4 switching fabric modules on the device. 

4.1 

 

Installing the NSQ1FAB04B0 

1.

 

Face the rear panel of the device. 

2.

 

Identify the slot to install the switching fabric module, and remove the filler panel from the slot. 
This manual uses slot 7 as an example. 

3.

 

Place the switching fabric module vertically with the surface-mounted components facing left. Pull 
outward the ejector levers and gently push the switching fabric module in along the slot guide rails 

until the switching fabric module is in close contact with the backplane. (See callout 1 in 

Figure 3 

.) 

4.

 

Push the ejector levers inward. (See callout 2 in 

Figure 3 

.) 

5.

 

Tighten the captive screws with a Phillips screwdriver to secure the switching fabric module in the 
slot. (See callout 3 in 

Figure 3 

.) 