Displaying Device Information 

The MS8000 allows you to display the current information of the server. You can check the information 

in real time against the normal range. This greatly facilitates the server maintenance. 

Select 

System Management

, and then select the 

Device Status

 tab to enter the page as shown in 

Figure 4-6.  

Figure 4-6 

Device status list 

 

 

Parameters of the device status are described in Table 4-2. 

Table 4-2 

Parameters of the device status 

Field 

Description 

Item

 

Component name of the device.

 

Current

 

Value of the current running status of the component.

 

Lower Critical 

Lower critical threshold of the running status of the component. 

Note: When the actual value is under this threshold, the device 
experiences a sever problem. Please contact H3C for technical help. 

Lower Non-Critical 

Lower non-critical value of the running status of the component. 

Note: When the actual value is between this threshold and the lower 
critical threshold, the device experiences a common error. Please check 
the corresponding component. 

Up Critical 

Upper critical threshold of the running status of the component. 

Note: When the actual value is under this threshold, the device 
experiences a sever problem. Please contact H3C for technical help. 

Up Non-Critical 

Upper non-critical threshold of the running status of the component. 

Note: When the actual value is between this threshold and the upper 
critical threshold, the device experiences a common error. Please check 
the corresponding component. 

 

To view the latest device information, click 

Refresh

Summary of Contents for MS8000

Page 1: ...H3C MS8000 Media Switch Server User Manual Hangzhou H3C Technologies Co Ltd http www h3c com Manual Version T2 08019E 20081202 C 2 01...

Page 2: ...G Vn G PSPT XGbus N Bus TiGem InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co Ltd All other trademarks that may be mentioned in this manual are the property of their respective o...

Page 3: ...terface operations for the MS8000 5 Compliance and Safety Manual for MS8000 Describes the compliance and safety specifications of the MS8000 Conventions The manual uses the following conventions GUI c...

Page 4: ...Documents Provides several categories of product documentation such as installation operation and maintenance Technical Support Document Product Support Software Provides the documentation released w...

Page 5: ...cting the Ground Wire 2 5 Connecting the AC Power Cable 2 6 Connecting the Console Cable and Network Cable 2 6 After Installation 2 7 3 Initial Configuration 3 1 Prerequisites 3 1 Configuration Tasks...

Page 6: ...isplaying VOD Traffic Statistics 4 12 Displaying Forwarding Traffic Statistics 4 12 5 Compliance and Safety Manual for MS8000 5 1 Regulatory Compliance Information 5 1 Regulatory compliance standards...

Page 7: ...eams z Placed inside the iVS the MS8000 is to distribute unicast media streams VOD of the audio and video history data The MS8000 is compatible with the all the H3C series of video encoders It reads t...

Page 8: ...n On Hardware exceptions occur to the system ALM Red Off The MS8000 is performing power on self test POST or no alarms exist Steady on The MS8000 is operating normally RUN Green Off The MS8000 is oper...

Page 9: ...Max power consumption 400 W Serial interface One RJ 45 connector with the default baudrate being 115200 bps Operating temperature 5 C to 40 C 41 F to 104 F Storage temperature 40 C to 70 C 40 F to 15...

Page 10: ...d equipment safety and shall not form short circuit or contact with the neutral wire of the high voltage electrical network z Keep the working environment clean Dust buildup will cause electrostatic a...

Page 11: ...nsequence caused thereby Installing the MS8000 in a Rack You can install your MS8000 to a standard 19 inch rack manufactured by H3C or other vendors the rack should be able to bear the weight of the M...

Page 12: ...outer slide rails Step3 Lift the MS8000 to align the inner slide rails with the outer slide rails and push the MS8000 slowly inside the rack along the slide rails until the mounting brackets contact...

Page 13: ...ts accessories and the cables z Make sure the workbench is well grounded and is stable The MS8000 is shipped with feet You need to remove the stickers from the feet and fasten the feet to the appropri...

Page 14: ...eep the cables loose between the interfaces and the fasten points Connecting the Ground Wire To ensure human and equipment safety against lightning and interference the MS8000 must be grounded reliabl...

Page 15: ...2 6 Connect the power cable You are recommended to connect the power cable to a single phase three wire power socket You need to make sure that the neutral point of the power socket is properly groun...

Page 16: ...ed check the following z The MS8000 is installed securely with all screws fixed tightly z No objects are placed on the MS8000 z The power to use meets the requirements of the MS8000 z The MS8000 is gr...

Page 17: ...figuration Tasks z The MS8000 is installed in the Linux operating system Its default settings are msserver1 for the hostname 192 168 0 30 24 for the IP address on eth1 as shown in Figure 1 3 192 168 0...

Page 18: ...r1 vi etc sysconfig network Type i to enter the edit mode of the configuration file Set the file content to HOSTNAME msserver and then save to exit After the modification press Esc and then enter wq i...

Page 19: ...tric 1 RX packets 1171606 errors 0 dropped 0 overruns 0 frame 0 TX packets 202306 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 192266150 183 3 MiB TX bytes 46015753 43...

Page 20: ...ffect Main parameters in the ms conf configuration file are described in Table 3 2 For other parameters not mentioned in this table it is recommended to use the default settings Table 3 2 Main paramet...

Page 21: ...ng MS8000 Services Step1 After configuration use the msserver restart command to restart the MS8000 services to make the configuration take effect root msserver msserver restart Step2 After that use t...

Page 22: ...for illustration For more information about users refer to the User Management section on page 4 9 z The parameters displayed in grey on the configuration pages cannot be modified Login and Logout Log...

Page 23: ...are idle without operation for 10 minutes the system logs you out automatically Log in again for operations Logging Out To log out of the MS8000 you can click Quit in the navigation tree and confirm...

Page 24: ...VM server CC IP IP address of the call control service on the VM server MS ID MS8000 ID used to identify the media switch server uniquely in the video surveillance system Note The MS ID must be uniqu...

Page 25: ...grading Software z Before upgrading the software back up the current configuration file For more information refer to the Exporting Importing Configuration section on page 4 3 z Do not power off the d...

Page 26: ...tual value is under this threshold the device experiences a sever problem Please contact H3C for technical help Lower Non Critical Lower non critical value of the running status of the component Note...

Page 27: ...e classified into 7 levels emergency alert critical error warning notice and information The first two are displayed red in the interface The meaning of the log levels are z Emergency Indicates a seve...

Page 28: ...nter the page displaying the operation logs Figure 4 9 Operation log list z Click Refresh to view the latest log information z Only the logs of past three months can be queried and displayed Querying...

Page 29: ...plays the result matching the query conditions Exporting Logs The logs record the system running status When errors occur in the system you can export the logs for troubleshooting To export logs follo...

Page 30: ...configuration and management operations including creating editing and deleting common administrators In addition the super administrator has the preempt login right over other users that is the logi...

Page 31: ...the user name and password Step4 Click OK Deleting a User z Only the super administrator has the permission to delete users from the system z Super administrator is the default user and cannot be rem...

Page 32: ...tem performs the operation and displays the result later If you select multiple users to reset password you can click Continue after the first is changed successfully Changing Password z It is recomme...

Page 33: ...fic statistics click Refresh as shown in Figure 4 14 Displaying Forwarding Traffic Statistics Select Traffic Statistics and then select the Forwarding Traffic tab to enter the page as shown in Figure...

Page 34: ...4 13 Figure 4 16 Forwarding traffic statistics...

Page 35: ...00 3 2 z EN 61000 3 3 z EN 61000 4 4 z EN 61000 4 5 z EN 61000 4 6 z EN 61000 4 8 z EN 61000 4 11 z GB 9254 z GB 17625 1 z YD T993 Safety z UL 60950 1 z CAN CSA C22 2 No 60950 1 z IEC 60950 1 z EN 609...

Page 36: ...ence problem and the expenses incurred therefrom shall be covered by the customers This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 o...

Page 37: ...operation instructions and precautions carefully to minimize the possibility of accidents The Note Caution Warning and Danger items in other manuals do not cover all safety precautions that should be...

Page 38: ...iegen den nationalen Sicherheitsvorschriften W hrend der Arbeit mit den Produkten sind deshalb grunds tzlich alle Sicherheitsvorschriften und spezifischen Sicherheitshinweise genau zu beachten Das f r...

Page 39: ...erbindung stets als letztes getrennt wird z z Do not block ventilation openings while the system is on and keep at least 5 cm distance from ventilation openings and walls or other things which may blo...

Page 40: ...sleitungen stellen f r die Arbeit der Ausr stung erforderliche Energie zur Verf gung Direkter oder indirekter Kontakt z B durch feuchte Gegenst nde mit Hochspannung und Wechselstromversorgung kann zu...

Page 41: ...t follow the local rules and regulations The personnel who perform high voltage operations should be qualified for high voltage and AC operations Warnung Die Nichtbeachtung der Sicherheitsvorschriften...

Page 42: ...chaltet werden bevor die Zuleitung angebracht oder entfernt wird z z Before the power cable is connected it must be confirmed that the power cable and label comply with the requirements of the actual...

Page 43: ...nnung und Wechselstrom oder Arbeiten auf Stahlt rmen und masten w hrend eines Gewitters sind verboten Um die Ausr stung vor Besch digung durch Blitzschlag zu sch tzen ist eine ordnungsgem e Erdung erf...

Reviews: