1  Identifier 

The module identifier LSQM1SDNB0 is in the upper right corner of the front panel. 

2  About the module 

The LSQM1SDNB0 is an SDN automation module built with server components required for 
ADCampus solutions. Plug and play, it supports fully automated deployment at small and 
medium-sized campus networks. It can deliver controller, authentication, and address assignment 
functions, eliminating the need for installing physical servers. 

Figure 1 LSQM1SDNB0 front panel 

 

(1) USB ports (3 in total) 

(2) VGA connector 

(3) Management Ethernet port 

(4) Management Ethernet port LED (LINK/ACT) 

(5) Console port (CONSOLE) 

(6) Shutdown LED and button (SHUTDOWN) 

(7) Ejector lever 

(8) Captive screw 

 

3  Specifications 

Table 1 Module specifications 

Item Specifications 

Hard disk 

480GB SSD 

Memory 

Two memory slots 

Standard configuration: 64 GB (two 32GB memory bars) 

Dimensions (H × W × D) 

40 × 399 × 355 mm (1.57 × 15.71 × 13.98 in) 

Weight 

3.40 kg (7.50 lb) 

Power consumption 

102 to 124 W 

Hot swapping 

Not supported 

Ports 

 

3 × USB2.0 ports (used by technical support for debugging only) 

 

1 × VGA connector 

 

1 × 10/100/1000BASE-T management Ethernet port 

 

1 × console port (used by technical support for debugging only) 

Ambient temperature 

 

Operating: 0°C to 45°C (32°F to 113°F) 

 

Storage: –40°C to +70°C (–40°F to +158°F) 

Summary of Contents for LSQM1SDNB0

Page 1: ... ports 3 in total 2 VGA connector 3 Management Ethernet port 4 Management Ethernet port LED LINK ACT 5 Console port CONSOLE 6 Shutdown LED and button SHUTDOWN 7 Ejector lever 8 Captive screw 3 Specifications Table 1 Module specifications Item Specifications Hard disk 480GB SSD Memory Two memory slots Standard configuration 64 GB two 32GB memory bars Dimensions H W D 40 399 355 mm 1 57 15 71 13 98 ...

Page 2: ...agement Ethernet port LED LINK ACT Steady green A 10 100 1000M link is present on the port Flashing green The port is sending or receiving data at 10 100 1000 Mbps Off No link is present on the port Shutdown LED SHUTDOWN Steady green The module is operating Flashing green The module is being shut down You can shut down the module only after the LED turns off Off The module is not operating 5 Insta...

Page 3: ...5 2 Removing the module IMPORTANT Before removing the module press the shutdown button on the module for a minimum of 2 seconds until the shutdown LED flashes green You can remove the module only after the shutdown LED turns off To remove the module 1 Use a Phillips screwdriver to loosen the captive screws on the module until all pressure is released 2 Simultaneously open the ejector levers of the...

Page 4: ...5 BOM 3123A1VF iv 6 Software upgrade For information about upgrading the software see the release notes for the module Copyright 2019 New H3C Technologies Co Ltd The information in this document is subject to change without notice ...

Reviews: