background image

Manual version: APW102-20191215 

BOM: 3123A1VF

 

ii 

Item Specifications 

Ambient humidity 

 

Operating: 5% RH to 95% RH, noncondensing 

 

Storage: 5% RH to 95% RH, noncondensing 

 

 

NOTE: 

  To verify the compatibility of the card with the software release you are using, see the release 

notes. 

  For information about transceiver modules and cables available for the card, see the cards and 

transceiver modules compatibility matrixes for the device. 

 

Table 2 10/100/1000BASE-T management Ethernet port specifications 

Item Specification 

Standard 802.3, 

802.3u, and 802.3ab 

Auto-MDI/MDIX Supported 

Cable 

Category 5 or above twisted pair cable 

Transmission distance 

100 m (328.08 ft) 

Rate and duplex mode 

10/100/1000 Mbps, full-duplex 

 

4  LEDs 

Table 3 LED description 

LED Status 

Description 

10/100/1000BASE-T 
management Ethernet port 
LED (LINK/ACT) 

Steady green 

A 10/100/1000M link is present on the port. 

Flashing green 

The port is sending or receiving data at 10/100/1000 
Mbps. 

Off 

No link is present on the port. 

Shutdown LED 
(SHUTDOWN) 

Steady green 

The module is operating. 

Flashing green 

The module is being shut down. You can shut down the 
module only after the LED turns off. 

Off 

The module is not operating. 

 

5  Installing and removing the module 

 

CAUTION: 

  Wear a reliably grounded ESD wrist strap or ESD gloves when installing or removing the module.

  Do not touch the components on the module. 

 

The module can be installed in a horizontal or vertical slot. When installing the module in a horizontal 
slot, make sure its component side faces up. When installing the module in a vertical slot, make sure 
its component side faces left. 

The installation and removal procedures are the same for horizontal and vertical slots. The following 
procedures install and remove the module in a horizontal slot. 

Summary of Contents for LSQM1SDNB0

Page 1: ... ports 3 in total 2 VGA connector 3 Management Ethernet port 4 Management Ethernet port LED LINK ACT 5 Console port CONSOLE 6 Shutdown LED and button SHUTDOWN 7 Ejector lever 8 Captive screw 3 Specifications Table 1 Module specifications Item Specifications Hard disk 480GB SSD Memory Two memory slots Standard configuration 64 GB two 32GB memory bars Dimensions H W D 40 399 355 mm 1 57 15 71 13 98 ...

Page 2: ...agement Ethernet port LED LINK ACT Steady green A 10 100 1000M link is present on the port Flashing green The port is sending or receiving data at 10 100 1000 Mbps Off No link is present on the port Shutdown LED SHUTDOWN Steady green The module is operating Flashing green The module is being shut down You can shut down the module only after the LED turns off Off The module is not operating 5 Insta...

Page 3: ...5 2 Removing the module IMPORTANT Before removing the module press the shutdown button on the module for a minimum of 2 seconds until the shutdown LED flashes green You can remove the module only after the shutdown LED turns off To remove the module 1 Use a Phillips screwdriver to loosen the captive screws on the module until all pressure is released 2 Simultaneously open the ejector levers of the...

Page 4: ...5 BOM 3123A1VF iv 6 Software upgrade For information about upgrading the software see the release notes for the module Copyright 2019 New H3C Technologies Co Ltd The information in this document is subject to change without notice ...

Reviews: