Manual version: APW102-20191215
BOM: 3123A1VF
ii
Item Specifications
Ambient humidity
•
Operating: 5% RH to 95% RH, noncondensing
•
Storage: 5% RH to 95% RH, noncondensing
NOTE:
•
To verify the compatibility of the card with the software release you are using, see the release
notes.
•
For information about transceiver modules and cables available for the card, see the cards and
transceiver modules compatibility matrixes for the device.
Table 2 10/100/1000BASE-T management Ethernet port specifications
Item Specification
Standard 802.3,
802.3u, and 802.3ab
Auto-MDI/MDIX Supported
Cable
Category 5 or above twisted pair cable
Transmission distance
100 m (328.08 ft)
Rate and duplex mode
10/100/1000 Mbps, full-duplex
4 LEDs
Table 3 LED description
LED Status
Description
10/100/1000BASE-T
management Ethernet port
LED (LINK/ACT)
Steady green
A 10/100/1000M link is present on the port.
Flashing green
The port is sending or receiving data at 10/100/1000
Mbps.
Off
No link is present on the port.
Shutdown LED
(SHUTDOWN)
Steady green
The module is operating.
Flashing green
The module is being shut down. You can shut down the
module only after the LED turns off.
Off
The module is not operating.
5 Installing and removing the module
CAUTION:
•
Wear a reliably grounded ESD wrist strap or ESD gloves when installing or removing the module.
•
Do not touch the components on the module.
The module can be installed in a horizontal or vertical slot. When installing the module in a horizontal
slot, make sure its component side faces up. When installing the module in a vertical slot, make sure
its component side faces left.
The installation and removal procedures are the same for horizontal and vertical slots. The following
procedures install and remove the module in a horizontal slot.