22
•
If the IRF fabric is integrated, only the MAD IP address of the master takes effect. The master
cannot establish a BFD session with any other member. If you execute the
display bfd
session
command, the state of the BFD sessions is
Down
.
•
When the IRF fabric splits, the IP addresses of the masters in the partitioned IRF fabrics take
effect. The masters can establish a BFD session. If you execute the
display bfd session
command, the state of the BFD session between the two devices is
Up
.
Examples
# Assign a MAD IP address to IRF member 1 on VLAN-interface 3.
<Sysname> system-view
[Sysname] interface vlan-interface 3
[Sysname-Vlan-interface3] mad ip address 192.168.0.1 255.255.255.0 member 1
# Assign a MAD IP address to IRF member 2 on VLAN-interface 3.
[Sysname-Vlan-interface3] mad ip address 192.168.0.2 255.255.255.0 member 2
Related commands
mad bfd enable
mad nd enable
Use
mad nd enable
to enable ND MAD.
Use
undo mad nd enable
to disable ND MAD.
Syntax
mad nd enable
undo mad nd enable
Default
ND MAD is disabled.
Views
VLAN interface view
Management Ethernet interface view
Predefined user roles
network-admin
Usage guidelines
Do not configure ND MAD together with LACP MAD or BFD MAD, because they handle collisions
differently.
When you configure ND MAD on a VLAN interface, follow these restrictions and guidelines:
Category Restrictions
and
guidelines
ND MAD VLAN
•
Do not enable ND MAD on VLAN-interface 1.
•
If you are using an intermediate device, perform the following tasks:
{
On the IRF fabric and the intermediate device, create a VLAN for ND
MAD.
{
On the IRF fabric and the intermediate device, assign the ports of ND
MAD links to the ND MAD VLAN.
{
On the IRF fabric, create a VLAN interface for the ND MAD VLAN.
•
If no intermediate device is used, connect each IRF member device to all
other member devices.