levelsmart
™
Wireless Autofill
9
Leaving the Level Sensor at the pool side, go back to the Valve
Controller (Fig.1.3)
When looking at the Valve Controller, you should see the yellow
(Action) LED flash once per second, 30 times. After this, the yellow
LED will flash every 4 seconds for a further 2 minutes. Finally, the
green (Level Sensor) LED light will illuminate. This solid green Level
Sensor LED indicates a successful pairing and that the intended
location for the Level Sensor in the pool is a good one.
If a solid green Level Sensor LED does not appear at the end of the
2.5 min, then the Valve Controller will either go back into a pairing
mode (the three LED’s scrolling from bottom to top), or a solid yellow
Action LED will illuminate.
If the unit goes back into either of these conditions, we need to move the Level Sensor or Antenna to different
loations so that they can better see each other. Alternatively, the Antenna’s cable may need to be extended using
the optional 25-foot cable.
If the system does not go back into pairing mode, simply unplug the power supply for 10 seconds before plugging
it back in again.
f) Mount the Level Sensor
Once a successful pairing has occurred, we can go ahead and install the Level Sensor. Before doing so, bring the
water to the desired level.
It is critical to thoroughly clean / scrub the area where the Level Sensor is to be installed. Now thoroughly dry the
area above the water line where the Level Sensor is to be mounted.