background image

levelsmart

Wireless Autofill

levelsmart

Wireless Autofill

Follow us on

Plumb the valve into the designated water fill line, or “T” 

it into the pool return plumbing after the filter and pump 

equipment from a nearby water source. You can use a water 

spigot, or “T” from a nearby irrigation line or similar. Add a 

pressure regulator if desired.
Fill the pool to the desired 

water level.
Make sure the valve solenoid 
is in the “OFF” position (see right).

For best results, mount the Valve Controller in a protected 

area out of direct sunlight and rain exposure. This component 

is weather-proof rated, but is always better tucked away from 

the elements if possible.
Mount the valve controller using the mounting screws 

provided in the accessory pack.
Use the wire nuts provided to connect the Valve Controller 

wires to the valve wires.
Connect the Valve Controller to the power transformer with 

the two pin plug, then plug into power source.
All 3 LED lights will repeatedly flash in sequence from the 

bottom to the top. This indicates that the unit is in pairing 

mode. Move on to the next step while this is taking place.

Connect all antennas and tighten them.
Place antenna tip in desired mounting position off the ground 

and 8-12 inches away from any metal.

Make sure Valve Controller is flashing in a sequence 

indicating it is in pairing mode.
Take sensor to pool and remove magnet above the mounting 

location. Leave on coping and watch the pairing process 

take place at Valve Controller. The yellow ‘ACTION’ light will 

flash for about 2.5 minutes.
Once Pairing is successful, a solid green LED will be seen on 

the sensor.
If pairing is not successful, place the Valve Controller into 

pairing mode by unplugging and plugging it back in. Then, 

place the magnet on the sensor for at least 16 second and 

remove. Once removed, repeat step 4.

Clean/scrub the area where the Water Level Sensor is to be 

mounted.
Mount the water level sensor where the desired water is 

about 0.5 - 1.5-inches up on the sensor.
Knead the epoxy thoroughly and spread on the dry back 

suface of the sensor. Firmly press the sensor against the 

mounting surface for at least 90 seconds, being sure that the 

sensor is sitting 0.5 - 1.5-inches into the desired water level.

INSTALL THE VALVE

STEP 1

INSTALL & CONNECT VALVE CONTROLLER

STEP 2

CONNECT ANTENNAS TO VALVE CONTROLLER

STEP 3

PAIR SENSOR & VALVE CONTROLLER

STEP 4

ADHERE SENSOR AND MOUNT ANTENNA

STEP 5

Valve Controller

Valve

Level Sensor

ROTATE

QUICK START GUIDE

 