8. FUNCTIONS
The device can execute the following functions, depending on pro gramming:
FUNCTION “THERMOMETER”
This function will be activated when the saved switching temperature ON
equals the switching temperature OFF. All three LEDs and the relay are switched
off and will lose their functionality. The device only shows the temperature.
FUNCTION “HEIZEN” (HEATING)
This function will automatically be activated when the set ON temperature is
lower than the OFF temperature. The LED
“Heizen”
will be on if the registered
temperature is equal to or lower than
T “ON”
. The relay is switched off if the
measured temperature is equal to or higher than
T “OFF”
.
Example:
When you set a switch-on threshold of 21°C and a switch-off threshold
of 22°C the device will automatically recognize that a heating process is taking
place (switch-off threshold is higher than switch-on threshold) and shows this via
the LED
„Heizen“
.
Temperature
T OFF
T ON
HEATING
Switch-ON-point
Switch-OFF-point
Time
Temperature
T OFF
T ON
HEATING
Switch-ON-point
Switch-OFF-point
Time