4.
Place component box (1) on a
clean and level surface.
Put adapters (2) on top of the
component box and fix with
12x M10x25 cylinder head
screws with washers.
ATTENTION: slide the 6mm
tubes through the
corresponding holes of the
component box.
5.
Put cardboard padding under
the marked areas of
component box and arch tips
and tilt box so that the arches
(3) can be fixed with 12x
M10x25 cylinder head screws
with washers while the box is
held by a second person.
6.
Connect the arch tips with the
cable guide module (4) using
the 4x M10x100 hex head
screws, 8x washers and stop
nuts.
7.
Pull rope through arch square
tube to exit through the top
hole.
Assemble arch, pulley and
pulley cover plate as depicted
(fit cover plate noses in
corresponding notches).