![H.Koenig AGE8WV Operation Manual Download Page 8](http://html.mh-extra.com/html/h-koenig/age8wv/age8wv_operation-manual_574498008.webp)
7
VII. MAINTENANCE
●
Shut off power supply before cleaning cabinet.
●
Take out wines and shelves, and then clean the cabinet with soda water first and with
clean water.
●
Do not use soap or detergent for the cabinet.
●
Clean the cellar regularly.
VIII. TROUBLESHOOTING
Symptoms
Possible cause
Solutions
No cooling
o
Plug not put in
o
Low voltage
o
Fuse broken
o
Put in the plug
o
Ensure normal voltage
o
Change fuse
Not cold
enough
temperature
inside
o
The wine cooler is
placed too near
heat source;
o
Bad ventilation;
o
Fans don’t work;
o
The door is not
closed tightly or
opened too
frequently or for
too long time;
o
Keep the wine cooler away from
sunshine or other heat source;
o
Place the wine cooler in the area
with good ventilation and keep
things away from the fans;
o
Check whether the plug is
connected or change the fan;
o
Close the door tightly and don’t
open the door too frequently or for
too long time.
Peculiar smell
inside wine
cooler
Check whether there
is any sour inside
Wrap the source or take it out
Inside light flash
o
Set temperature
higher than inner
temperature;
o
The automatic
defrost function
start to work
o
Adjust the adjustor
o
Normal function. No repair needed
Frost on the
cold sink
。
Too much humidity or
too low temperature
inside the case
Output the plug, stop the power, and
defrost by hand, Connect power again
when the ice thaws
Adeva SAS / H.Koenig Europe - 8 rue Marc Seguin, 77290 Mitry-Mory, France
www.hkoenig.com
-
-
- Tél: +33 1 64 67 00 01