In general, the F010-P will always function at Operator level. The information displayed is dependant
upon the SETUP-settings. All pulses generated by the connected flowmeter are measured by the
F010-P in the background, whichever screen refresh rate setting is chosen. After pressing a key, the
display will be updated very quickly during a 30 second period, after which it will slow-down again.
Fig. 3: Example of display information during process.
For the Operator, the following functions are available:
Display flowrate
This is the main display information of the F010-P. After selecting any other information, it will
always return to this main display automatically.
When "-------" is shown, then the flowrate value is too high to be displayed.
Piegraph indication
This 10 segment Piegraph gives a quick impression about the actual value in relation to its
measuring range in a scale of 0-100%.
As soon as the input value is 5% above the calibrated measurement range, the piegraph
starts flashing.
Low-battery alarm
When the battery voltage drops, it must be replaced. At first "low-battery" will flash, but as
soon as it is displayed continuously, the battery MUST be replaced shortly after!
Only original batteries supplied by the manufacturer may be used, else the guarantee and
liability will be terminated. The remaining lifetime after the first moment of indication is
generally several days up to some weeks.
Fig. 4: Example of low-battery alarm.
Range error
As soon as the input value is 5% outside the calibrated measurement range, the piegraph
starts flashing. Meanwhile, LO RANGE or HI RANGE will be displayed.
Alarm 01-03
When "alarm" is displayed, please consult Appendix B: problem solving.