37
TITANIUM 400 AC/DC
EN
Settings
Designation
Adjustable
settings
Description & advice
Pre-gas
0 - 60 sec.
Time to purge the torch and to protect the area with gas before ignition
Starting current
10 - 200 %
This starting bearing current is a phase before the current rise ramp.
Starting time
0 - 10 sec.
Rising current
0 - 60 sec.
Current rise ramp.
Welding current
3 - 400 A
Welding current.
Évanouisseur
0 - 60 sec.
Down slope current.
End current
10 - 200 %
This stopping stop current is a phase after the current descent ramp.
End duration
0 - 10 sec.
Post-gas
0 - 60 sec.
Duration for which gas is released after the arc has stopped. It protects the weld pool
and the electrode against oxidisation when the metal is cooling down.
AC wave shape
AC waveform.
Frequency
welding
20 - 300 Hz
Frequency of polarity reversals welding - pickling
Penetration and clea-
ning (%)
20 - 60 %
Percentage of the welding period dedicated to pickling (default 30-35%)
AC time
0 - 10 sec.
Welding time in AC TIG welding
DC time
0 - 10 sec.
Welding time in DC TIG welding
THE TIG DC or AC TIG POINTAGE
SPOT (TIG DC or AC)
This welding mode allows the pre-assembly of the parts before welding. Scoring can be manual by trigger or delayed with a predefined scoring delay.
This pointing time allows a better reproducibility and the realization of non-oxidized point (accessible in the advanced menu).
Settings
Designation
Adjustable
settings
Description & advice
Pre-gas
0 - 60 sec.
Time to purge the torch and to protect the area with gas before ignition
Welding current
3 - 400 A
Welding current.
Spot
, 0 - 60 sec.
Manual or a defined time.
Post-gas
0 - 60 sec.
Duration for which gas is released after the arc has stopped. It protects the weld
pool and the electrode against oxidisation when the metal is cooling down.