21
GYSPOT ARCPULL 200
EN
MANUAL SETTINGS
OVERHEATING DEFECT
OVERVOLTAGE DEFECT
COM. DEFECT
Info
Soft gene V0.0
Hard gene V0.0
Soft gun V0.0
Hard gun V0.0
PRESSED KEY
zone de
message
Product reset
:3 sec
to reset
Configuration
> Pregas > 100ms
Postgas 500ms
Language EN
Product reset
Info
Synergic Settings
> Material > Fe
Gas ON
Electrode Ring
THK. elec. 1.5 mm
Main Menu
> Settings
Manual Mode
Configuration
t
ms
I
A
100
200
message
area
Manual Settings
Start-up > Q = 0
OVERHEATING DEFECT
MOTOR DEFECT
Ring 1.5mm
Fe Gas
+1
2.0
message
area
Press the keys G+ and G- to browse the different values (arcing and attachment coeffi-
cients, duration, currents, height) of the drawn arc process (see chapter «Drawn arc wel-
ding process»).
Press the keys D+ and D- to modify the values (coefficients, duration, current, height).
Push the Menu/Validate button
to confirm the manual settings and return to the manual welding screen.
Push the return button
to ignore the settings and return to the Main Menu.
Range of settings for the manual
mode
Comment
Arcing
-5 to 5 (default value 0)
The default value is set to ensure optimal arcing and stop the arc
from breaking up when pulling the electrode while limiting the
short-circuit current.
Reducing the arcing increases the risk of the arc breaking up
Increasing the arcing forces an unnecessary high short-circuit
current.
Penetration
and cleaning
10 to 60 A
0 to 200 ms
Arc
0 to 200A*
Limited to 100A if product is connected to a 110Vac ±15% power
supply.
0 to 500 ms
Attachment
-5 to 5 (default value 0)
The default value is set to ensure optimal attachment of the elec-
trode onto the metal support.
0 to 50 ms
Height
0.5 mm to 5 mm
CONFIGURATION
OVERHEATING DEFECT
OVERVOLTAGE DEFECT
COM. DEFECT
Info
Soft gene V0.0
Hard gene V0.0
Soft gun V0.0
Hard gun V0.0
PRESSED KEY
zone de
message
Product reset
:3 sec
to reset
Configuration
> Pregas > 100ms
Postgas 500ms
Language EN
Product reset
Info
Synergic Settings
> Material > Fe
Gas ON
Electrode Ring
THK. elec. 1.5 mm
Main Menu
> Settings
Manual Mode
Configuration
t
ms
I
A
100
200
message
area
Manual Settings
Start-up > Q = 0
OVERHEATING DEFECT
MOTOR DEFECT
Ring 1.5mm
Fe Gas
+1
2.0
message
area
Press the keys G+ and G- to move the left cursor (Pregas, Postgas, Language, Reset
machine, Info).
When the items Pregas, Postgas or Langue are highlighted, press the keys D+ and D- to
modify their value.
Range of settings
Comment
Pregas
NoGas then from 0.2s to 3s
For a good gas protection when welding, it is recommended to set a
minimum pre-gas of 0.2s and a gas flow between 10 and 12L/min.
Postgas
NoGas or from 0.2s to 3s
To weld using a gas coating, it is recommended to have a minimum
postgas setting of 0.2s.
Language
FR, GB, DE, NL, ES, IT, RU
Push the return button
to return to the Main Menu.
Reset machine
OVERHEATING DEFECT
OVERVOLTAGE DEFECT
COM. DEFECT
Info
Soft gene V0.0
Hard gene V0.0
Soft gun V0.0
Hard gun V0.0
PRESSED KEY
zone de
message
Product reset
:3 sec
to reset
Configuration
> Pregas > 100ms
Postgas 500ms
Language EN
Product reset
Info
Synergic Settings
> Material > Fe
Gas ON
Electrode Ring
THK. elec. 1.5 mm
Main Menu
> Settings
Manual Mode
Configuration
t
ms
I
A
100
200
message
area
Manual Settings
Start-up > Q = 0
OVERHEATING DEFECT
MOTOR DEFECT
Ring 1.5mm
Fe Gas
+1
2.0
message
area
When the «Reset Machine» is selected from the Configuration menu, pressing menu/vali-
date
opens the reset machine sub-menu.
Press menu/validate
for 3 seconds to confirm product reset.
Push the return button
to return to the Configuration menu and cancel product
reset.
Summary of Contents for GYSPOT ARCPULL 200
Page 48: ...48 GYSPOT ARCPULL 200 RU 10 11 2...
Page 50: ...50 GYSPOT ARCPULL 200 RU g h 10 CISPR 11 2009 a b c d e f 10 IP21 12 5...
Page 56: ...56 GYSPOT ARCPULL 200 RU 12 cm 049000 048157 048164 3 3 059634 059641...
Page 87: ...87...
Page 88: ...88 GYS SAS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex France...