background image

 

14 

 
ACCESSORIES 

 

Height level rods                  

The measuring tool includes 2 height level rods of two different lengths. 

 

Magnetic holder

 

This magnetic holder is developed to suit most vehicle models on the market. 
Use it when a round or oval hole <Ø35 mm is specified as the zero point on the 
vehicle dimension data sheet. 

 

Height measuring rods 

 

3 height rods are included. 
Rod height is determined by the data sheet and should allow for the specified 
reading to be observed when the rod has been locked in place on the measuring 
arm. 
Insert the rod into the measuring head at the front end of the measuring arm. 
Position the flat side of the rod towards the “release” mark, set it at the desired 
height and secure by twisting it to the “lock” position 

 

Level 

On the measuring head is a level to compare height differences. 

 

Measuring sockets and tips 

GYSMETER includes: 
- 5 measuring tips (2 x Ø25, 2 x Ø35 mm and 1 x Ø60 mm) 
- 16 sockets sized from 10-26 mm 
- 9 M201 adaptors 6-18 
- 1 90° holder 
Sockets and tips snap into the top of the height measuring rods. 
 

 

TECHNICAL SPECIFICATIONS 

  

 

The precision of the level will depend upon the extension length of the measuring arm. 

 

 

Refer to the table below for the height tolerances : 

 

Extension in mm 

Height tolerance in mm 

900 

approx. 0,5 

1800 

approx. 1,0 

2650 

approx. 1,5 

 

 

Measuring range: 

- Normal measure: from 900 to 2650mm 
- Short measure: from 400 to 2150mm 

 

 

 

 

 

Datum rods’ difference in height = 100 mm 

 
 

 

Summary of Contents for GYSMETER 052093

Page 1: ...r 4 Display functions 13 Menus 4 Menus 13 Accessoires 5 Accessories 14 Sp cifications techniques 5 Technical specifications 14 Effectuer des mesures 6 Measuring 15 Mesures courtes 8 Short measures 17...

Page 2: ...o l aimant int gr risque de les endommager ENTRETIEN G n ralit s Le syst me de mesure Gysmeter est compos d un bras de mesure lectronique de haute pr cision qui n cessite un entretien sp cifique pour...

Page 3: ...e au centre de la pointe de mesure Remarque si le syst me de mesure a perdu sa position et n indique pas 900 mm en position r tract e il doit tre red marr comme indiqu ci dessus MODE NORMAL Il s agit...

Page 4: ...4 FONCTIONS DE L AFFICHEUR MENU ON 900 2650 400 2150 OFF Appuyer 2 sec Appuyer 1 sec Mesure comparative et Appuyer 3 sec ON 900 400 OFF 1 sec Mesure comparative 2 sec 2 sek...

Page 5: ...rences en hauteur Douilles et pointes de mesure Le syst me de mesure contient 5 pointes de mesure 25 35 et 60 mm 9 douilles 10 26 mm 9 adaptateurs M201 6 18 1 pi ce de renvoi 90 Placer les douilles e...

Page 6: ...er enti rement le bras de mesure et appuyer le bouton ON 0 au moins 5 secondes l cran s teint Le bras de mesure toujours repli appuyer de nouveau le bouton ON O l affichage indique 900 900 mm Le bras...

Page 7: ...es surtout si c est difficile de voir l affichage pendant la mesure Appuyer le bouton HOLD pour sauvegarder les valeurs mesur es Pour retourner appuyer de nouveau le bouton HOLD 5 Lire les valeurs af...

Page 8: ...esure en 400 2150 en appuyant le bouton ON O pendant 2 secondes Placer une pige gradu e avec une hauteur de 100 dans le bras de mesure UTILISATION DU LOGICIEL GYS TECH T l chargement http www gys weld...

Page 9: ...l quipement La garantie est valable un an partir du jour de livraison et couvre les d fauts de mat riel condition que l quipement ait t entretenu normalement La garantie suppose que L utilisation et...

Page 10: ...le bras de mesure vers le point de fixation du c t oppos et monter la fixation magn tique B Lire la longueur de ce c t C Comparer les valeurs Monter la fixation magn tique un point sym trique et non...

Page 11: ...ER measuring tool is composed of a high precision electronic measuring arm which necessitates a specific maintenance in order to maintain its performances on the long term Please follow all instructio...

Page 12: ...tes the value 900 which represents the minimum length between the heigth calibration rod and datum heigth rod center Note If display does not read 900 switch off by holding down the On 0 key for a few...

Page 13: ...13 DISPLAY FONCTIONS MENU ON 900 2650 400 2150 OFF Press 2 sec Press 1 sec Comparative measurement and Press 3 sec ON 900 400 OFF 1 sec 2 sec 2 sek Comparative measurement...

Page 14: ...sition the flat side of the rod towards the release mark set it at the desired height and secure by twisting it to the lock position Level On the measuring head is a level to compare height difference...

Page 15: ...suring arm This is done by compressing the arm completely altogether and pressing the ON 0 key until the display switches off With the measuring arm still compressed press the ON 0 key and the digital...

Page 16: ...key again briefly 5 Read the measuring arm s display and compare the symmetry cross measurement value with the value on the data sheet It can be advantageous here to enter the measured value in the d...

Page 17: ...YS TECH SOFTWARE The GYSTECH software can be downloaded by clicking at the following address http www gys welding com distFiles GYSMETER_install exe As the software starts up click on the flag of the...

Page 18: ...18 SPARE PARTS...

Page 19: ...to the opposite side of the vehicle and fit the magnetic attachment to an equivalent measuring point B Take a similar length reading on this side C Compare readings Mount the magnetic attachment on a...

Reviews: