19
EASYCUT K25 / EASYCUT K35F
MADE IN FRANCE
EN
MADE IN FRANCE
CONSUMABLES INSPECTION (ASSEMBLY AND DISASSEMBLY, SEE P.16)
Parts
Actions
Solutions
Nozzle
Check the for damage and surface wear.
Replace the nozzle when it looks damaged (traces of
burns).
Tip
Visually check the tip’s internal hole.
OK
NOK
Replace the tip if the inner diameter is enlarged or
distorted.
Diffuser
Check for damage and wear on the surface and inside the diffuser.
Check that the fumes’ exhausts are not obstructed.
Replace the diffuser if the surface is damaged or
worn, or if fume exhausts are obstructed.
Electrode
Visually check the electrode’s internal hole.
OK
NOK
Replace electrode when the insert is used (removal of
1.5 mm).
TROUBLESHOOTING
Anomalies
Causes
Remedies
The machine delivers no power.
The green working indicator is on.
The thermal protection indicator is conti-
nuously on.
The thermal protection of the welding unit is
on.
Wait until the end of the cooling phase.
The machine delivers no power.
The green working indicator is on.
The thermal protection ondicator blinks 2
times then lights off (K35F).
The error indicator blinks quickly (K35F)
The input voltage is higher than 230V + 15%
for plasma K25 and K35F.
Check your electrical network or your elec
-
tric generator then switch off and on your
machine.
The machine delivers no power.
The green working indicator is on.
The thermal protection indicator blinks quickly
(K35F).
The error indicator blinks quickly (K35F).
Torch defect.
Check your torch assembly.
By pressing the trigger, the air flows but the
pilot arc is not working.
Consumables shabby.
Check and change the consumables, then
switch off and on your machine.
The electrical arc switches off after about 3
seconds.
Earth problem.
Check the earth clamp is well connected to
a clean area (not painted and not fat) of the
part to cut.
If you feel tingling sensation, when the unit
is on and you put your hand on the welding
unit’s body.
The welding unit is not correctly connected to
the earth.
Check the plug and the earth of your electrical
network.
The unit does not supply power. The three
lights flash when switching on the unit (K35F)
The unit is switched on with the trigger
pressed
Release the trigger. If the problem remains
send back the machine
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported.
Summary of Contents for EASYCUT K25
Page 2: ...MADE IN FRANCE 2 EASYCUT K25 EASYCUT K35F FIG 1 5 2 3 1 EASYCUT K35F 4 EASYCUT K25 2 3 5 1...
Page 3: ...3 EASYCUT K25 EASYCUT K35F MADE IN FRANCE FIG 2 EASYCUT K25 EASYCUT K35F 2 1 3 4 2 1 3...
Page 42: ...42 EASYCUT K25 EASYCUT K35F MADE IN FRANCE RU MADE IN FRANCE 1 90 2 3 1 30 2 30 90 3 4...
Page 65: ...65 EASYCUT K25 EASYCUT K35F MADE IN FRANCE EASYCUT K35F...