CONNECT 5

EN

PROGRAMME RECALL BY THE CONSOLE  

(PRODUCTS WITH TFT SCREENS)

When the console takes control over the machine, it can then recall programmes. The name 

of the recalled programme is displayed in the main window.

P1 : TUB 2 mm

PROGRAMMES ALLOCATION 

(PRODUCTS WITH KEYPAD)

TIG 300 DC

TIG TITAN 400 DC

Access to allocation table and matching table : 

The programme allocation is fixed by default to the first five saved settings.

If no saved setting is recorded on the product : this does not change the operation of the automated system mode, each pro-

gramme will match the default context or free programme.

CONNECT-5 RECOGNITION MODES 

(PRODUCTS WITH KEYPAD)

TIG 300 DC

TIG TITAN 400 DC

When plugging in the automated system, 2 recognition modes exist.

1/ A direct recognition mode detecting the short circuit on AUTODETECT, the recognition takes place and the machine starts or goes into CONNECT-5 

configuration.

2/ An indirect recognition mode detecting the impedance on the remote control. A keypad message will appear requesting precision for the type of 

remote control connected.

 CONNECT-5 selection mode.

THE «FREE» PROGRAMME

The «free» programme matches the current context by default. 

The MMI (man machine interface) gives access to different settings:

IHM with TFT 

screen

The higher bar is accessible but with restrictions :

- Process : TIG – MMA 

- Type : DC – AC – SYNC  - AC MIX

- Ø : OK

-  Sub-process : STD – PULSE – SPOT … : OK

- Type of trigger : 2T only

- Arcing : OK

- Option : deactivated

- Files : OK

- Welding and settings cycle : OK

Keypad

- Process & Arcing : TIG-HF – TIG-LIFT – MMA 

- Type of trigger : deactivated for 2T only

- Sub-process : STD - PULSE - Easy Pulse - SPOT : OK

- SAVE / RECALL : deactivated

- Welding and settings cycle : OK

ARC ON

L’ARC ON is a piece of information sent by the welding machine and equal to the state of the welding arc.

During a welding cycle, the ARC ON is at 0 while the arc is on (from I_Start to I_Stop). 

L’ARC ON is at 1 while the arc is off (during the Pregas or Postgas phases but also if the arc stops because the machine encountered a problem).

Summary of Contents for CONNECT 5

Page 1: ...73502_V3_19 03 2018 FR 2 4 CONNECT 5 EN 5 7 ES 8 10 IT 11 13...

Page 2: ...P2 P3 P4 P5 OK TUB 2mm TUB 4mm TUB 5mm TUB 6mm TUB 7mm Mode S lection des programmes P1 P2 etc Une fen tre d di e permet de d placer le curseur sur les cinq programmes du Connect 5 et de cocher le pr...

Page 3: ...onnaissance directe par la d tection du court circuit sur AUTODETECT la reconnaissance est faite et le poste d marre ou se met en configuration CONNECT 5 2 Un mode de reconnaissance indirecte par la d...

Page 4: ...cours POSITION 1 0 6V 1 1V programme 1 POSITION 2 1 2V 1 6V programme 2 POSITION 5 2 8V 3 3V programme 5 Pour un VCC 5 V ou 10 V et un automate n utilisant pas un r seau de r sistance une r gle de 3 s...

Page 5: ...P1 P2 P3 P4 P5 OK TUB 2mm TUB 4mm CONNECT 5 P1 P2 P3 P4 P5 OK TUB 2mm TUB 4mm TUB 5mm TUB 6mm TUB 7mm Mode Programmes selection P1 P2 etc A dedicated window is used to move the cursor through the fiv...

Page 6: ...ration 2 An indirect recognition mode detecting the impedance on the remote control A keypad message will appear requesting precision for the type of remote control connected CONNECT 5 selection mode...

Page 7: ...5 V or 10 V and a robot not using a resistance network a cross multiplication rule is used C GND COMMUN D START on off welding control output activates on contact E AUTODETECT a strap between E and C...

Page 8: ...UB 7mm Modo Selecci n de los programas P1 P2 etc Una ventana espec fica permite desplazar el cursor sobre los cinco programas del Connect 5 y de seleccionar el programa a asociar Al presionar la ruede...

Page 9: ...te detecci n de una impedancia sobre el conector de Control a Distancia CAD Un mensaje en el teclado aparece para indicar una precisi n sobre el tipo de control conectado que se selecciona con la rued...

Page 10: ...ndos C GND COM N D START salida T N Todo o Nada de control de soldadura funciona por contacto E AUTODETECT una conexi n entre E y C permitir al equipo reconocer el modo de reconocimiento directo F ARC...

Page 11: ...P2 P3 P4 P5 OK TUB 2mm TUB 4mm TUB 5mm TUB 6mm TUB 7mm Modo Selezione dei programmi P1 P2 etc Una finestra dedicata permette di spostare il cursore sui cinque programmi del Connect 5 e di selezionare...

Page 12: ...Un modo di riconoscimento indiretto attraverso il rilevamento di un impedenza sul connettore del Comando A Distanza CAD Apparir un mes saggio con la richiesta di precisare il tipo di CAD connesso da...

Page 13: ...di resistenza si effettua una regolazione 3 C GND COMUNE D START uscita T N Tutto o Niente di comando saldatura funziona su contatto E AUTODETECT un collegamento tra G e C permetter al dispositivo di...