![GYS 069824 Operating Manual Download Page 30](http://html1.mh-extra.com/html/gys/069824/069824_operating-manual_2281113030.webp)
30
Operating manual
GYSPOT COMBI ARCPULL
Translation of the original
instructions
CONFIGURATION
Configuration
> Pregaz > 0.2s
Postgaz 0.2s
Langue FR
Reset machine
Info
Press the G+ and G- keys to move the left cursor (Pre-Gas, Post-Gas, language, ma
-
chine reset and data).
When the Pre-gas, Post-gas or language options are highlighted, press the D+ and D-
keys to change their value.
Settings range
Comments
Pre-Gas
Then no gas from 0.2 - 3 s
For gas-shielded welding, it is recommended to have a Pre-Gas of at
least 0.2 s with a flow rate between 10 - 12 l/min.
Post-Gas
Then no gas from 0.2 - 3s
When welding under a gas shield, it is recommended to have Post-Gas
limit of at least 0.2 s.
Language
FR, EN, DE, NL, ES, IT, RU
Press the return button
to go back to the main menu.
Machine Reset
Reset machine
: 3sec
pour valider
When ‘Machine Reset’ is selected from the settings menu, pressing Menu/Enter
will
bring up the machine’s reset submenu.
Hold down the Menu/Enter button
for three seconds to confirm resetting the device.
Press the return button
to go back to the settings menu and to cancel resetting the
device.
Information panel
Info machine
Soft géné V1.0
Hard géné V2.0
Soft pistolet V1.0
Hard pistolet V2.0
The information panel shows the device’s software and hardware part numbers and that of
the welding gun (if connected).
UPDATE VIA THE USB PORT
In order to benefit from new synergies and improved software, the user can update the aluminium section using the USB
port on the front panel. To do this, contact the GYS after-sales service team and follow the procedure.
TOOLS FOR THE WELDING GUN
Included as an optional extra, welding attachments to aluminium/steel is possible with the accesso
-
ries listed at the end of the manual (threaded studs and insulating nails, etc.).