12
GYSFLASH 10.36/48 PL
Step
3
: Test
Sulfated battery test
Step
7
: Floating mode
(
- 40.8 V /
- 54.4 V)
Maintaining the battery charge level at its maximum.
Step
4
: Desulfation
(
- 47.4 V /
- 62 V)
Battery desulfation algorithm.
• Lithium charging curve :
The GYSflash 10.36/48 PL uses an advanced 8-step Lithium charging curve that guarantees the optimal performance of your
lithium battery.
Step
1
: Analysis
Analyses the state of the battery (charge level, polarity inversion,
wrong battery…)
Step
5
: Test
Charge hold test.
Step
2
: Recovery
(
- 2 A /
- 2 A)
Recovery algorithm following a deep discharge.
Step
6
: Complement
Reduce current charge to reach 100% charge level.
Step
3
: Charging
(
- 10 A /
- 8 A)
Fast charging at maximum current up to 90%.
of the charge level.
Step
7
: Equalization / Balancing
Balancing the battery cells
/
/
LiFePO4
54 V
57.6 V
43.2 V
Li-ion
54 V
58.1 V
41.5 V
Step
4
: Absorption
Constant voltage charging to bring the charge level to 98%.
/
/
LiFePO4
51.8 V
55.2 V
41.4 V
Li-ion
52.7 V
56.7 V
40.5 V
Step
8
: Floating mode
Maintain the battery charge level at its maximum with main-
tenance charge every 10 days.
/
/
LiFePO4
51.75 V
55.2 V
41.4 V
Li-ion
52.7 V
56.7 V
40.5 V
• Estimated charge time :
Charging current
Lead-acid
Lithium
8 A
10 A
8 A
10 A
Battery capacity
20 Ah
50 Ah
100 Ah
160 Ah
60 Ah 150 Ah
230 Ah
8 Ah
30 Ah
120 Ah 160 Ah 30 Ah 140 Ah 230 Ah
Charge timing 0% >90%
2 h
6 h
12 h
20 h
6 h
15 h
23 h
1 h
3.5 h
15 h
20 h
3 h
14 h
23 h
EN
Translation of the original instructions