11
GYSFLASH 20.12/24 PL
EN
Charging current 7 / 15 / 20 A :
Selection designed to choose the most suited charging current based on the type and size of the battery
(lead-acid or lithium).
Charging current
7 A
15 A
20 A
Battery capacity
Pb
12 V
15
60 Ah
60
90 Ah
90
300 Ah
24 V
15
60 Ah
60
240 Ah
-
LFP
12 V
7
15 Ah
15
25 Ah
25
300 Ah
(21 45 Ah EqPb*) (45 75 Ah EqPb*)
(75 900 Ah EqPb*)
24 V
7
15 Ah
15
240 Ah
-
(21 45 Ah EqPb*) (45 690 Ah EqPb*)
*Lead battery corresponding : A lithium battery has a better starting performance (CCA) than a lead-acid battery. This is why some
lithium battery manufacturers indicate the battery lead equivalent (EqPb) corresponding to the capacity of a lead-acid battery with
the same starting performance. For instance, a LFP battery of 10 Ah will have the same starting performance as a lead-acid battery
of around 30 Ah.
• Lead-acid charging curve :
The GYSflash 20.12/24 PL features a 7 step charging curve designed to ensure optimal charging of lead-acid batteries.
U
I
1
2
3
4
5
6
7
Analysis
Recovery
Test
Desulfation
Charge
Absorption
Floating
charge
CHARGE
OK
Le
d
Max 12h
<1s
Max 5h
<1s
Max 20h
Max 8h
No limit
Step
1
: Analysis
Analyses the battery state (charge level, polarity inversion,
wrong battery…)
Step
5
: Charge
(
7 A - 15 A - 20 A /
7 A - 15 A)
Maximum current fast charge to reach 80% charge level.
Step
2
: Recovery
(
3 A - 5 A - 7 A /
3 A - 5 A)
Recovering damaged elements due to a prolonged deep
discharge.
Step
6
: Absorption
(
14.6 V /
29.2 V)
Constant voltage charge to reach 100% charge level.
Step
3
: Test
Sulfated battery test
Step
7
: Floating charge
(
13.6 V /
27.2 V)
Maintains battery charge level at its maximum.
Step
4
: Desulfation
(
15.8 V /
31.6 V)
Battery desulfation algorithm.