PSP Series User Manual
50
SV
Command
Description
The SV command sets the voltage output level.
Syntax
SV <parameter> <CR>
ASCII
53 56 <parameter> 0D
HEX
Parameter
<parameter> Description
xx.xx
Voltage value( 5 characters, 2 decimal
places)
Example
SV 10.50<CR>
Sets the voltage output to 10.5V.
SU
Command
Description
The SU command sets the voltage output limit.
Syntax
SU <parameter> <CR>
ASCII
53 55<parameter> 0D
HEX
Parameter
<parameter> Description
xx
Voltage value( 2 characters, no
decimal)
Example
SU 11<CR>
Sets the voltage limit to 11V.
SI
Command
Description
The SI command sets the current limit. The power
limit will be automatically altered to suit.
Syntax
SI <parameter> <CR>
ASCII
53 49<parameter> 0D
HEX
Parameter
<parameter> Description
x.xx
Current limit value( 4 characters, two
decimal places)
Example
SI 1.10<CR>
Sets the current limit to 1.10A.