SAFETY INSTRUCTIONS
3
Safety Guidelines
General
Guideline
CAUTION
Do not place any heavy object on the power
supply.
Avoid severe impact or rough handling that
could lead to damaging the power supply.
Do not discharge static electricity to the power
supply.
Do not block or obstruct the cooling fan vent
openings.
Do not disassemble the power supply unless
you are qualified as service personnel.
(Measurement categories) EN 61010-1:2001 specifies the
measurement categories and their requirements as follows. The
PSP series power supplies fall under category II.
Measurement category IV is for measurement performed at the
source of low-voltage installation.
Measurement category III is for measurement performed in the
building installation.
Measurement category II is for measurement performed on the
circuits directly connected to the low voltage installation.
Measurement category I is for measurements performed on
circuits not directly connected to Mains.
Power Supply
WARNING
AC Input voltage: 115/230 VAC±15%.
Connect the protective grounding conductor of
the AC power cord to an earth ground, to avoid
electrical shock.
Fuse
WARNING
Fuse type: Slow blow T3.15A/250V (230V
input), T6.3A/250 (115V input).
Make sure the correct type of fuse is installed
before power up.
All manuals and user guides at all-guides.com