background image

 

  GDM-9060/9061 Series Excel Add-In Manual 

8

 

Uninstallation 

Follow the procedures described in this section when the Excel Add-In or one 

of  the USB drivers needs to be updated or removed. 

 

Uninstalling the 
USB driver 

To update or remove the USB driver, it must be 

uninstalled from the Windows Device Manager.   

 

1.

 

Launch 

Device Manager

 from the Start menu. 

Start

Control Panel

Device Manager 

(Windows XP, Windows 7/8/10: 32 bit or 64 bit) 

 

2.

 

For CDC driver: Double-click 

Ports (COM & 

LPT)

. Right-click 

GDM- Series CDC 

(COMXX) 

and choose the Uninstall option.   

 

 

For TMC driver: Double-click 

Test and 

Measurement Devices

. Right-click 

Test and 

Measurement Device (IVI)

 and choose the 

Uninstall option. 

 

 

Summary of Contents for GDM-9060 Series

Page 1: ...Excel Add In GDM 9060 9061 Series GDM 9060 9061 Series Excel Add In Manual VERSION NO 1 00 ISO 9001 CERTIFIED MANUFACTURER ...

Page 2: ...her language without prior written consent of Good Will company The information in this manual was correct at the time of printing However Good Will continues to improve products and reserves the right to change specifications equipment and maintenance procedures at any time without notice Good Will Instrument Co Ltd No 7 1 Jhongsing Rd Tucheng Dist New Taipei City 236 Taiwan ...

Page 3: ...of Contents 3 TABLE OF CONTENTS INTRODUCTION 4 Overview 4 SETUP 5 Connecting to GDM 9060 9061 5 Installation 7 Uninstallation 8 Configuration 10 DATA LOGGING REMOTE CONTROL 13 View Add In Software Version 21 ...

Page 4: ...raphing functions Overview About Icon Save Load Multimeter Settings Setup Run Logging Worksheet Run Pause Stop Setup Multimeter Connect to Multimeter Connect to Multimeter Clicking this icon will allow you to establish a connection to the DMM Save Load Multimeter Settings Clicking this icon will let you save or load settings to from the multimeter Setup Multimeter Clicking this icon will allow you...

Page 5: ...MM 1 Press Menu button 2 Go to Interface tab 3 Further go to the field of Interface 4 Select USB option for interface 5 Go to the field of Protocol 6 Set the interface to either USBCDC or USBTMC 7 Press Exit Menu to confirm the settings and exit Note The baud rate does not need to be set when either USB CDC or USB TMC interface is used Alternatively the RS232 connection is the easiest way to use t...

Page 6: ...igure the DMM 1 Press Menu button 2 Go to Interface tab 3 Further go to the field of Interface 4 Select RS232 option for interface 5 Go to the field of BaudRate 6 Set the desired baud rate for RS232 7 Press Exit Menu to confirm the settings and exit ...

Page 7: ...ad the USB driver from the GW Instek Website 3 Follow the instructions on the Hardware Wizard to finish the installation Installing the Excel Add In 1 On the User Manual CD go to the Excel Add in subdirectory under the Software directory and execute the Setup exe file 2 If the Microsoft User Account Control Shield appears allow the setup file to be executed 3 Follow the InstallShield Wizard to ins...

Page 8: ... the USB driver it must be uninstalled from the Windows Device Manager 1 Launch Device Manager from the Start menu Start Control Panel Device Manager Windows XP Windows 7 8 10 32 bit or 64 bit 2 For CDC driver Double click Ports COM LPT Right click GDM Series CDC COMXX and choose the Uninstall option For TMC driver Double click Test and Measurement Devices Right click Test and Measurement Device I...

Page 9: ...n press the OK button The driver will uninstall automatically Uninstalling the Excel Add In 1 From the Windows Start menu select the Start All Programs GWINSTEK DMM 2 Select Yes to uninstall the product 3 The Uninstaller will automatically finish the uninstallation ...

Page 10: ...ntrol Panel System Device Manager 2 For RS232 CDC connections check which COM port the device is assigned to and make note of it 3 For TMC connections check to make sure the DMM is recognized in the Test and Measurement node Configure the Add In 1 From the Windows Start menu select Start All Programs GWINSTEK DMM GDM 906x Excel Addin GDM 906x Excel Addin ...

Page 11: ... 2003 Go to the Tools menu and select the Add Ins option 4 The Add In will be shown in a custom tool bar 5 Click on the Connect to Multimeter icon 6 In the Connect window that appears click Search to scan for the DMM 7 After the DMM has been detected click on your DMM in the Select Address window A number of devices may be returned If the model name and serial number of your device are not returne...

Page 12: ... close automatically after the connection is successful 10 Move on to the Data Logging Remote Control chapter Disconnect Press Disconnect to end the remote control session Cancel and Exit Press Close to exit from the Connection window without connecting or disconnecting ...

Page 13: ...on 2 The Set Up Multimeter window appears 3 Choose a measurement item 4 Choose the measurement range for DC Voltage DC Current AC Voltage AC Current Resistance 2W Resistance 4W Diode Capacitance Frequency and Period Choose the sensor and referenceR for TEMP 4WRTD Choose the sensor type and resolution for TEMP TC 5 Press OK to confirm the settings and exit 6 Press Exit to discard the settings and e...

Page 14: ...r Settings to File If saving a file choose a directory and filename Click Save to save the file The file will be saved as XXXXX DMM After a few moments if the save was successful a message Save File OK will appear Click OK If loading a file choose a previously saved setup and click Open A message Load File OK will appear if the setup is loaded successfully Click OK The panel will close automatical...

Page 15: ...gin Logging Data panel Immediately Choose this option to begin logging measurements as soon as the Play icon is pressed see page 19 for details At Time This option allows you to choose the exact time that the logging will start The start date hour minute and second can be chosen respectively On Receiving External Trigger This option will only start logging after the TRIG key is pressed on the DMM ...

Page 16: ...e DMM will trigger down to the number of hours minutes and seconds between each measurement 5 Use the Terminating Upon panel to set when to stop the data logging Number of Readings Configures the logger to stop after a set amount of measurements Duration Sets the logger to stop logging measurements after a set amount of time or number of readings ...

Page 17: ...No Chart This option will disable plotting a graph This is the default option Graph This will plot each point in a graph as soon as it is logged Strip Chart This option creates a graph that allows you to view detailed sections of the graph using Excel Format controls Number of Data Points This option allows you to specify the number of data points to graph This number cannot exceed 1000 ...

Page 18: ...istogram option will open a new sheet and perform statistical analysis on the logged data in real time so that a histogram can be created The average median standard deviation as well as minimum and maximum values will also be calculated This option will disable the graphing option mentioned above The number of bins for the data and thus the interval is determined automatically by the software Thi...

Page 19: ... to be logged If the Chart or Histogram options were selected then they will also be plotted as the data is logged Press the Pause icon to pause logging Press the Run icon again to resume Press the Stop Icon to stop data logging prematurely Each time you use the data logging function a new sheet will be created for the data and for the histogram data if the Histogram option is enabled Note that th...

Page 20: ...GDM 9060 9061 Series Excel Add In Manual 20 Chart Example Data statistics Excel Add In icons Logged data Chart Histogram Example Data statistics Excel Add In icons Logged data Histogram ...

Page 21: ...MOTE CONTROL 21 View Add In Software Version View software version 1 Click on the About Icon to view the software version number About Icon 2 The About Multimeter splash screen will appear with software version number ...

Reviews: