POWER SUPPLY FOR INFINITY

®

 LIGHTING SYSTEMS

INSTALLATION GUIDE

Specifications are subject to change without notice. Every effort has been made to ensure that the information provided in this manual is accurate. 

GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www.gvalighting.com for additional information.

PS-INF 3000

& PDC INF

WARNING

1.

Only qualified personnel should be permitted to install, replace, or service this equipment.

2.

Only use attachments and/or accessories specified by GVA Lighting.

3.

Follow instructions for wall, shelf, or ceiling mounting as recommended by GVA Lighting.

4.

Use properly rated and stable input voltage within the range of 100~240V. (Use of non-rated and/or unstable AC input voltage may result in

severe damage to the product.

5.

Do NOT, under any circumstance, modify or disassemble this product. Doing so may result in a fire, electric shock and/or severe damage to

the product.

6.

Do NOT touch power cables or power plugs in such circumstances as a lightning storm, as this may cause electric shock.

7.

Any severe physical impact on the product, other than what is specified by GVA Lighting, may cause certain components to fall out of place

within and break, which may cause fire or electric shock. In such an event, do not operate the product. Contact your authorized GVA Lighting 

representative for support.

8.

Protect the power cord from being walked on or pinched.

9.

Do NOT destroy, process, or place the product close to any heating device as this may result in damages to the product.

10.

Do NOT bend or twist power cords, power plugs, cables, or wires with excessive force as this may result in damages to the product.

11.

Do NOT place any heavy object on the product as this may result in damages to the product.

12.

Do NOT touch power cables with wet hands and/or when the power supply is running as this may cause electric shock.

13.

 Do NOT use any non-rated power sockets and/or power strips with many other devices jointly plugged in. The wire of non-designated capacity

may cause fire due to build up heat emission. 

14.

 In case of product malfunction or unusual events, such as electrical burning smell and smoke, immediately turn OFF and contact GVA

Lighting.

15.

 Do NOT install this product in an unstable environment, such as 

o

n moving objects, or on unstable surface

s

. Improper installation may result

in dismounting of the product and may result in equipment damages, fires, personal injury, and death.

16.

Do NOT install the product near a poisonous gas or chemically unstable atmosphere as it may cause fire.

17.

 Do NOT install the product near a strong magnetic or electric field. It may result in equipment damages, fires, electric shock, and

 

personal

injury.

18.

Do NOT move or transport this product with any power cables connected to the source devices. Damages may occur to the cables, plugs, or

jointing connectors of the cables due to forcible bending and stress. This may cause damages to the waterproof seal of the product, making

it subject to fire, electric shock, or shorted circuit.

19.

When disconnecting the equipment, always hold the plugs of power cords or cables. Improper pulling of the cords or cables may cause

damages to the waterproof seal of the product. This may result in equipment damages, shorted circuits, fires, electric shock, and personal 

injury.

20.

 Do NOT use any other power cords or connection cables than what is recommended/provided by the manufacturer directly. Use of untested,

unauthorized, or substituted power cords and/or connection cables may be a cause for malfunction, fire, electric shock, or severe damages 

to the product. Also, such use of improper or undesignated power cords or connection cables will void product warranty.

21.

 Always leave the power OFF when connecting or disconnecting the power cords or connection cables to avoid electric shock or damages to

the product.

22.

Do NOT use aggressive cleaning agents, such as paint thinner or benzene to clean the exterior

 of the product

. It may cause scratches on

the surface, erasing proper indications, identification labels, or instructions on the exterior, which may be a cause for misuse and 

improper operation of the product.

23.

This equipment must be externally grounded using a customer-supplied ground wire before power is applied. Contact the local electrical

inspection authority or a licensed electrician if uncertain that suitable grounding is available.

24.

Do not work on the system or connect or disconnect cables during periods of lightning activity.

25.

No serviceable parts inside the product. Do not open.

GVA Lighting, Inc. 2771 Bristol Circle, Oakville, Ontario L6H 6X5

Tel: + 1 905 569 6044  Email: [email protected]

gvalighting.com

IG-PS-INF-3000, 06-06-2019

     

Page 

4

 / 1

3

Summary of Contents for PDC INF

Page 1: ...POWER SUPPLY FOR INFINITY LIGHTING SYSTEMS INSTALLATION GUIDE GVA Lighting Inc 2771 Bristol Circle Oakville Ontario L6H 6X5 Tel 1 905 569 6044 Email info gvalighting com gvalighting com IG PS INF 3000 06 06 2019 Page 1 13 ...

Page 2: ...cal errors Refer to www gvalighting com for additional information PS INF 3000 PDC INF REVISION HISTORY REVISION NUMBER REVISION DATE DESCRIPTION 1 2 September 08 2016 June 20 2017 July 06 2018 June 06 2019 Initial Release Aesthetic Adjustments Corrections addition of information Update of information 3 4 GVA Lighting Inc 2771 Bristol Circle Oakville Ontario L6H 6X5 Tel 1 905 569 6044 Email info g...

Page 3: ... G20337 POWER SUPPLY PS INF 3000 120VAC 1W N PE 60Hz 16A MAX 380VDC 1500W IP66 NA REV 1 G20338 POWER SUPPLY PS INF 3000 208 240VAC 2W PE 60Hz 16A MAX 380VDC 3000W IP66 NA REV 1 G20341 POWER SUPPLY PS INF 3000 220 230 240VAC 1W N PE 50Hz 16A MAX 380VDC 3000W IP66 EU REV 1 Before you begin Thank you for purchasing GVA s PS INF 3000 power supply unit Before installing the unit please read this instal...

Page 4: ...ble environment such as on moving objects or on unstable surfaces Improper installation may result in dismounting of the product and may result in equipment damages fires personal injury and death 16 Do NOT install the product near a poisonous gas or chemically unstable atmosphere as it may cause fire 17 Do NOT install the product near a strong magnetic or electric field It may result in equipment...

Page 5: ...akage current high touch current the power cable ground wire green or green yellow must be connected first to the AC Ground or PE Protective Earth terminal prior to connecting the other AC input wires NOTE Installation shall incorporate UL Listed or applicable local safety agency listing external surge protection rated 2500 Vpk or less for 150 to 300 Vac mains depending on jurisdiction installed i...

Page 6: ...0000 UP The area around the unit indicated with red must be kept clear at all times MIN 300mm 12in MIN 150mm 5 9in MIN 150mm 5 9in POWER SUPPLY FOR INFINITY LIGHTING SYSTEMS INSTALLATION GUIDE Specifications are subject to change without notice Every effort has been made to ensure that the information provided in this manual is accurate GVA Lighting Inc is not responsible for printing or clerical ...

Page 7: ...e information provided in this manual is accurate GVA Lighting Inc is not responsible for printing or clerical errors Refer to www gvalighting com for additional information PS INF 3000 PDC INF TYPICAL SYSTEM DIAGRAM PS INF 3000 NON DIMMING For non dimming INFINITY lighting systems CAUTION When routing cables through the cable entry be sure that the cables are formed in such a way as to remove any...

Page 8: ... provided in this manual is accurate GVA Lighting Inc is not responsible for printing or clerical errors Refer to www gvalighting com for additional information PS INF 3000 PDC INF TYPICAL SYSTEM DIAGRAM PS INF 3000 NON DIMMING FIGURE 2 JUNCTION BOX CONNECTION by others NOTE This is a sample drawing Actual junction boxes supplied by others may vary in appearance FIG 2 GVA Lighting Inc 2771 Bristol...

Page 9: ...AM PS INF 3000 NON DIMMING FIGURE 3 1 Junction Box Connection for G20337 Line Neutral Protective Earth North America NOTE This is a sample drawing Actual junction boxes supplied by others may vary in appearance FIGURE 3 2 Junction Box Connection for G20341 Line Neutral Protective Earth Europe NOTE This is a sample drawing Actual junction boxes supplied by others may vary in appearance GVA Lighting...

Page 10: ...is manual is accurate GVA Lighting Inc is not responsible for printing or clerical errors Refer to www gvalighting com for additional information PS INF 3000 PDC INF TYPICAL SYSTEM DIAGRAM PS INF 3000 NON DIMMING FIGURE 3 3 Junction Box Connection for G20338 Line Line Protective Earth North America NOTE This is a sample drawing Actual junction boxes supplied by others may vary in appearance GVA Li...

Page 11: ...ons are subject to change without notice Every effort has been made to ensure that the information provided in this manual is accurate GVA Lighting Inc is not responsible for printing or clerical errors Refer to www gvalighting com for additional information PS INF 3000 PDC INF TYPICAL SYSTEM DIAGRAM PS INF 3000 PDC INF DIMMING For dimming INFINITY lighting systems CAUTION When routing cables thro...

Page 12: ...this manual is accurate GVA Lighting Inc is not responsible for printing or clerical errors Refer to www gvalighting com for additional information PS INF 3000 PDC INF TYPICAL SYSTEM DIAGRAM PS INF 3000 PDC INF DIMMING FIGURE 5 PDC INF GVA Lighting Inc 2771 Bristol Circle Oakville Ontario L6H 6X5 Tel 1 905 569 6044 Email info gvalighting com IG PS INF 3000 06 gvalighting com 06 2019 Page 12 13 ...

Page 13: ...e information provided in this manual is accurate GVA Lighting Inc is not responsible for printing or clerical errors Refer to www gvalighting com for additional information PS INF 3000 PDC INF NOTES GVA Lighting Inc 2771 Bristol Circle Oakville Ontario L6H 6X5 Tel 1 905 569 6044 Email info gvalighting com IG PS INF 3000 06 gvalighting com 06 2019 Page 13 13 ...

Reviews: