THERMOSTAT TC40S - PE
PROGRAMMABLE DIGITAL - WHITE
USER MANUAL
I - INTRODUCTION
Technical parameters
Voltage
AC 230V, 50-60Hz
Amperage
16 A
Working environment
0ºC ~45ºC
Consumption
<0.3 W
Protection index
IP20
Programmable temperature
5ºC ~ 60ºC
Temperature control precision
0.5 ºC
Características Principais
Programs
6 daily, 3 weeklys
Probe reading options
3 (internal, external and both)
External dimensions
85mm x 85mm x 14mm
Material
PC + ABS
Screen background colo
Blue
Memory in case of electrical failure
Time and Programs
Child lock
Yes
Installation
Wall-Inserted Type
III - CAUTIONS FOR INSTALLATION
Fig. 1 - Thermostat opening
1 2 3 4
5
L1 N1
N
L
6
N
TC
Fig. 2 - Wiring diagram
Fig. 3 - Thermostat Installation
Heating
Manual Mode
Anti-Frozen
Child Lock
Probes Temperature
Clock
Buttons
Period
Set temperature
Week
V - THERMOSTAT INTERFACE
+
+
Button functions
Thermostat ON
Long Press
Thermostat OFF
Short Press
Thermostat ON
Short Press
----
Turn on
Turn Off
Daily and weekly
schedule
----
Toggle automatic /
manual mode
Child Lock
----
Set time and day
Increase temperature
0.5ºC continuously
----
Increase temperature
0.5ºC
Decrease temperature
0.5ºC continuously
----
Decrease temperature
0.5ºC
----
Advanced
Settings
----
----
----
Floor probe reading
VI - THERMOSTAT PROGRAMMING
TURN ON/OFF
Press the button to turn on the thermostat.
Press the button again to turn off the thermostat and cut the power to the
heating cable or mat.
Dear User:
Congratulations on choosing a thermostat. Please refer to this user
manual before installing/using the thermostat.
This thermostat is used to control the temperature of heating cables or
heating mats for electric underfloor heating in a given room, wether in a
domestic, commercial or industrial environment.
While we try to provide the best device possible, we are always available for
technical support. If you have any questions, please contact us.
II - TECHNICAL PARAMETERS AND MAIN CHARACTERISTICS
ATTENTION!
When being installed, this thermostat may cause an
electric shock. Make sure the installation is done by
a qualified electrician.
1. Installation should only be done when the electric supply is off, otherwise it can
damage the thermostat and cause an electric shock.
2. Choose the most suitable location for installing the thermostat (about 1,60m
above the floor). It must not be installed at eye level.
3. Installation should not be made at altitudes higher then 2000m above sea level.
IV - INSTALLATION
1. Separate the thermostat from the display using a screwdriver to press the
groove at the back of the thermostat and pushing the display upwards (fig.1).
2. Follow the wiring diagram (fig. 2) to connect the power, the heating cable
and the floor probe.
3. Use the two screws provided to fix the outer ring and the thermostat base
to the electrician's deep box previously installed (fig. 3) and make sure that it
is properly installed.
4. Attach the display to the four projections on the mounting plate and push it
downwards (never press the LCD display directly). The installation is complete.
Turn on the power to test the thermostat.
Heating Cable / Mat
16A
N (Neutral Wire)
L (Live wire)
AC220V, 50~60Hz
Floor Sensor