Selection of installation positions for indoor unit
• To be installed at the position where the air delivered from the unit can reach every corner of the
room;
• To avoid being affected by the outdoor air;
• To avoid blockage to the air inlet or outlet of the unit;
• To avoid too much oil smoke or steam;
• To avoid possible generation, inflow, lingering or leakage of flammable gases;
• To avoid high-frequency facilities (such as high frequency arc welders, etc.);
• To avoid the places where acid solutions are frequently used;
• To avoid the places where some special sprayers (sulfides) are frequently used.
• Not to install on top of the musical instruments,TV,computer etc.valuable appliance.
• Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarm
device might be erroneously triggered by the warm air from the unit);
p
Make sure of enough space for installation and maintenance.
• To take into consideration the operational convenience and safety in installation, It Is recommended
to ensure enough space between the unit and the walls.
Ceiling
Right side: 150mm (6“) and
above from wall
Leftside: 150mm(6“)
and above from wall
Above 100mm(4“)
Wall hanging plate
2300mm(7‘6“)
and above
Ground
Attention: lf there are some additional function devices to install on the air conditioner.Be
sure add to the installation space for the function devices.
p
Height limits of indoor and outdoor units.
• Either the indoor unit or the outdoor unit can be higher, but the height difference must comply the
stated requirements.
• Try to reduce the bending of the piping line as much as possible so as to avoid possible negative
impacts upon the performances of the units.
5m (16‘5“) max
Indoor unit
Outdoor
unit