EN
22
Operation via switch
Button
Push
Execution
b
1x
Fan ON Motor runs at level 1, LED (c) + 1 on.
b
2x
Motor runs at level 2, LED
(c)
+ 1
-
2 on.
b
3x
Motor starts at level 3, LED
(c)
+ 1
-
3.
b
4x
Motor starts at intensive level, LED
(c)
+ 1
-
4 starts.
Motor automatically switches back to level 3 after 5 minutes.
b
> 3sec.
Motor switches off
a
1x
Lighting OFF
a
1x long
Lighting dimmer
-
funktion
a
1x
Lighting OFF
b
> 5 sec.
Colour temperature adjustment ( only TW version )
Pressing and holding button (b) will start the color change ( 2700
-
6500K ) and the last value will also be stored when released.
( only available when the engine is stopped )
LED
-
Display
Information on the operating status of the cooker hood :
LED
c:
Display of operating status fan ON / OFF
c:
flashing: display of automatic follow
-
up time
.
(the hood automatically switches down by one power level every 5 minutes
until it is finally switched off)
1
Fan output level 1 (low motor output)
Press button b 1x
2
Fan output level 2 (medium motor output)
Press button b twice
3
Fan power level 3 (high motor power)
Press button b three times
i
Intensive level (motor automatically switches back to level 3 after 5 minutes)
Press button b 4x
f
Filter saturation display
.
When the red LED lights up / flashes, the metal filters must be cleaned (see
section Cleaning and care). The filter saturation indicator lights up after max.
15 operating hours (even when not cooking). After cleaning, press the reset
button (b) for about 10 seconds until the LED goes out.
( Only possible when
the device is switched on
-
TW function is deactivated when the red LED flashes ! )
rocker switch