Connecting the direct water
drain (see Fig. 2)
1.
Remove the screw cap and water
plug on the rear (middle) of the
appliance from the drain hole.
2.
Attach the water drain hose to
the connection.
Connecting the floor tray drain
(see Fig. 2)
1.
Remove the screw cap and water
plug on the rear (bottom) of the
appliance from the drain hole.
2.
Attach the water drain hose to
the connection.
Route the free end of the water
drain hose into a suitable drain or
container into which the
condensation is to drain.
NOTE
If the internal water tank is full, the
appliance automatically switches to
emergency stop.
“P1” lights up on
the display.
13.3
Set fan speed
Set the fan speed between low,
medium, high or AUTO (Automatic)
with button “G”.
13.4
Description of the
operating modes
Select the operating mode between
COOL, DRY, FAN and AUTO with
buttons “E” on the appliance.
COOL / cooling mode
•
Set temperature and fan speed.
•
All functions are available.
FAN / ventilation mode
•
Compressor does not run.
•
Set the fan speed.
•
The temperature cannot be set.
•
All other functions are available.
DRY / dehumidification mode
•
The appliance starts
automatically in cooling mode
with 25°C and the lowest fan
speed.
•
Temperature and fan speed
cannot be altered.
•
All other functions are available.
AUTO / automatic mode
•
The appliance starts
automatically in cooling mode
with 24°C.
•
Fan speed and temperature
cannot be altered.
14
Cleaning
Clean the mobile air conditioner
according to use and degree of
soiling, but at least every 4 weeks.
Always allow the mobile air
conditioner to cool down completely
before cleaning!
•
Clean the ventilation openings
and the filter at regular intervals
(approx. every 2 weeks) to
prevent the performance of the
mobile air conditioner from
deteriorating.
•
Wipe down the outside of the
mobile air conditioner with a dry
or slightly damp cloth.
•
Then rub the mobile air
conditioner completely dry.
•
Remove dust and soiling from
the ventilation openings using a
suitable soft brush.