4

GENERAL INSTALLATION DATA

This equipment is designed and sold for commercial use only by personnel trained and experienced 

in its operation and is not sold for consumer use in and around the home nor for use directly by the 
general public in food service locations. 

The GUSTO series gas charbroiler is equipped for the type of gas indicated on the nameplate 

mounted on the  front panel. All units are shipped from the factory for use with natural gas. The unit 
can easily be converted for use with propane gas: see propane gas.

-IMPORTANT-

INSTALL IN NON-COMBUSTIBLE LOCATIONS ONLY! 

Clearance from non-combustible 

construction must be 6" from back and sides.

The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE 

"ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND 

REGULATIONS.

IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT 

CAN/CGA-B149.1  NATURAL  GAS  INSTALLATION  CODE  OR  CAN/CGA-B149.2 

PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.

WARNING:  

Improper installation, adjustment, alteration, service or maintenance can 

cause property damage, injury or death.  Read the installation, operating and maintenance 

instructions thoroughly before installing or servicing the equipment.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance.  Keep the appliance area clear and free from combustibles.

For your protection, we recommend a qualified installing agency install this appliance. 

They should be familiar with gas installations and your local gas requirements. In any 

case, your gas company should be called to approve the final installation. In addition, 

there should be posted, in a prominent location, detailed instructions to be followed in the 

event the operator smells gas. Obtain the instructions from the local gas supplier.

This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the 
gas supply piping system during any pressure testing of that system at test pressures in excess of / 
PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system 
by closing its individual manual shutoff valve during any pressure testing of the gas supply piping 

system at test pressures equal to or less than 1/2 PSIG.

EXHAUST CANOPY

Open hearth broilers inherently create a good deal of heat and smoke and should be installed under 

an efficient exhaust hood with flame proof filters. A vertical distance of not less than 48" shall be 

provided between the top of the appliance and filters or any other combustible material.  Exhaust 

installation must conform to local codes.

AIR SUPPLY

Provisions for adequate air supply must be provided. 

LEVELING UNIT

This charbroiler is supplied with 4 feet which must be screwed into the body. Level unit by adjusting 

the (4) feet which have an adjustment of 1-3/4" for accurate and perfect line-up with other units. 

DO NOT INSTALL WITHOUT ATTACHING FEET - DO NOT REMOVE FEET.

CAUTION

CAUTION

Summary of Contents for Lava Rock AMLB24

Page 1: ... GAS CHARBROILER MODEL Lava Rock AMLB24 AMLB36 AMLB48 Radiant AMRB24 AMRB36 AMRB48 Installation Operation Parts Manual 2M Z15769 Rev 4 12 12 IL2422 ...

Page 2: ...are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance Please record the model number serial number voltage and purchase date in th...

Page 3: ... Designed with high performance 40 000 BTU H style cast iron burners every 12 of width Cast iron burners provide excellent broiling performance better heat distribution and maximum sectional control Heavy duty cast iron grates can be individually positioned flat or slanted to accommodate a variety of broiling needs Grates are reversible with a thin side for searing and a thick side for more delica...

Page 4: ...stibles For your protection we recommend a qualified installing agency install this appliance They should be familiar with gas installations and your local gas requirements In any case your gas company should be called to approve the final installation In addition there should be posted in a prominent location detailed instructions to be followed in the event the operator smells gas Obtain the ins...

Page 5: ...use with natural gas and you wish to convert to propane gas Follow these steps install the burner orifice hoods included with the unit as follows 1 Remove grill radiants and burners 2 Remove the burner orifice hoods and install the orifice hoods supplied 3 Replace the burners radiants and grill 4 Set manifold pressure to 10 inch water column A 1 8 pipe plug on the burner manifold can be removed fo...

Page 6: ...the yellow tips disappear and a hard blue flame is obtained PLACING LAVA ROCK ON GRATES FOR AMLB SERIES Open the lava rock bags and place rock evenly on grates Do not cover the grates with more than two layers of lava rock DO NOT PUT MORE THAN 5 LBS OF ROCK PER BURNER PLACING RADIANTS FOR AMRB SERIES After the unit is unpacked and installed place 2 radiants above each burner Install each radiant e...

Page 7: ...articular food products We recommend that you set the grate at the full tilt position to start This position allows the grease to run down the grate into the grease tray reducing flare ups Check water pans frequently and add a sufficient amount of water when necessary Hot water vapors rising from the water pans and through the combustion chamber helps reduce flare ups Exercise care when using your...

Page 8: ... 1 7 8 5 6 4 12 11 10 16 15 17 25 9 2 3 31 30 28 27 20 21 29 23 24 22 14 18 19 26 13 33 32 MODEL AMLB24 AMRB24 Model AMLB AMRB Gas Charbroiler SK2572 Rev 3 09 12 ...

Page 9: ...3 Z15872 AMRB48 AMLB48 15 VARIOUS 1 NAMEPLATE ALL 16 2M Z15720 1 GRAPHIC PANEL AMRB24 AMLB24 2M Z15721 AMRB36 AMLB36 2M Z15722 AMRB48 AMLB48 17 2R W498 2 3 4 KNOB AMLB24 AMRB24 AMLB36 AMRB36 AMLB48 AMRB48 18 2V 6671 2 3 4 PILOT VALVE 24 INCH 36 INCH 48 INCH 19 2K Z6050 1 MANIFOLD AMRB24 AMLB24 2K Z6051 AMRB36 AMLB36 2K Z6052 AMRB48 AMLB48 20 2P 1453 1 PIPE PLUG ALL 21 2K Z6192 2 3 4 PILOT BURNER 2...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 6 ...