Modular design of the matrix switch
G&D ControlCenter-Digital-160 ·
9
English
Up to three
power supply modules (5)
provide power to the matrix switch. If you use
at least two power supply modules, you can replace one of them during operation.
Installing or replacing components
Installing or replacing IO cards
IO cards can be installed (hot plug) or replaced (hot swap) during operation.
NOTE:
By distributing the load, power is supplied to all active power supply
modules.
The IO Card
CCD-IO16-Card-Fiber
uses components with laser technology which
comply with laser class 1.
They meet the requirements in accordance to
EN 60825-1:2014
as well as
U.S. CFR 1040.10
and
1040.11
.
Mind the following instructions when dealing with laser beams:
Avoid direct eye exposure to beam
Always connect optical connections or cover them with protection caps