32
A & C torch oscillation dwell orientation:
This momentary push button allows the operator to set the orientation of the A & C dwell
positions for the linear torch oscillator. This orientation is indicated on the display by an image of
the welding torch shown next to an image that symbolizes the welding carriage. Whenever this
button is pushed the image of the torch and welding carriage will change (flip) to acknowledge
the change in A & C dwell orientation. Also this push button determines the direction of the
oscillator center adjustment / steering direction inputs. For example; if the operator turns the
rotary knob for the oscillator center position adjustment / steering (located on the remote
pendant) to the left and the corresponding torch movement is to the right, the A & C dwell
orientation needs to be changed. See page 33 for the display screens that depict all
combinations of carriage direction and torch dwell position.
Note:
Changes in A & C dwell orientation can only be made while the carriage is at rest and not
in automatic cycle or while being manually jogged.
Carriage with locking
handles shown
Welding torch shown to the right
side of welding carriage
Wire feed drive wheels. Will rotate during
welding and whenever the wire feeder is
jogged in either forward or reverse