Technical data
53
Technical specification
Model
GJPACW1V-15 GJPACW1V-20 GJPACW1V-30
1
GJPACW1V-40 GJPACW1V-60
Heating output
2
kW
6.8
9.2
13.8
18.2
26
Input power
kW
1.2
1.7
2.6
3.5
5.0
Heating capacity
3
m
3
20 - 35
30 - 50
40 - 80
60 - 110
80 - 150
Operating voltage
230 VAC 1-phase 50 Hz
400 VAC
230 VAC
400 VAC
Operating current
A
5.23
7.50
11.4
4.47
15.2
8.5
Fuse size
A
10
16
13
20
16
Compressor
Rotary compressor
Scroll compressor
Refrigerant amount (R410a)
kg
0.9
1.0
1.2
1.3
1.9
1.85
Fan consumption
W
50
75
120
200
200
Rated air flow
m
3
/h
1600
2300
2300
4800
4800
Noise level (1 m)
dB(A)
47
51
54
56
58
Water connection
mm
50 mm
Rated water flow
m
3
/h
2.2
3
4.5
6
9
Pressure drop at rated flow
bar
0.12
0.10
0.10
0.10
0.12
Pressostat break value HP
bar
44 (makes again at 32 bar)
Pressostat break value LP
bar
0.2 bar (makes again at 1.5 bar)
Height
mm
725
750
750
880
880
Width
mm
525
580
580
720
720
Depth
mm
490
545
545
660
660
Weight
kg
50
61
60
80
87
135
1
GJPACW1V-30 can be either 1-phase or 3-phase.
2
Heating output measured at 24 °C / 19 °C outdoor temperature, DB / WB (Dry bulb / Wet bulb). Incoming water
temperature 27 °C.
3
Heating capacity should be seen as guide values for an insulated pool covered at night. The models are
designed for use during the period May - September (normal pool season).
E
A
A
D
B
C
OUTLET
INLET
F
G
Model
Dim.
GJPACW1V-15
GJPACW1V-20/30
GJPACW1V-40/60
A
490
545
650
B
265
317
400
C
523
557
720
D
545
580
740
E
725
750
880
F
115
115
110
G
92.5
92.5
120
Dimensions and connections
52