9
Caution:
Connect only to a circuit protected by a residual
current device. Test the RCD before each use of the
spa.
Attention:
Connecter uniquement a un circuit protege par un
disjoncteur differentiel. Toujours verifier l'efficacite du
disjoncteur differentiel avant d'utiliser le bain. Bonding
lugs. Cosses demise a la masse.
Use the copper
conductors only. Employer uniquement des
conduteurs de cuivre.
Nos stations thermales sont certifiées par les Services
de l'Essai d'Intertek NA Ltd. Ontario à CAN/CSA-
C22.2 No. 218.1-M89 et ANSI/UL 1563.
Parts with extra low voltage not exceeding 12v must be
inaccessible to a person in the spa. Earthed appliances must be
permanently connected to fixed wiring. Parts incorporating
electrical components, except remote control devices, must be
located or fixed so that they cannot fall into the spa. Appliances
should be supplied through an RCD having a rated residual
operating current not exceeding 30ma.
Means for disconnection must be used in fixed wiring in
accordance with wiring rules.
Important –
To allow the 240V GFCI to function properly, connect
the white Neutral wire from the spa to the Neutral terminal on the
GFCI breaker, not the Neutral bus in the GFCI breaker box. An
improperly connected Neutral causes the GFCI breaker to trip.
Summary of Contents for LX 11000
Page 13: ...11 European 1x32A Wiring Diagram Jumper L1 L2 L3 ...
Page 14: ...12 European 2x16A Wiring Diagram Jumper L2 L3 ...
Page 15: ...13 European 3x16A Wiring Diagram No Jumper ...
Page 48: ...46 Notes ...
Page 49: ...47 Notes ...
Page 50: ...48 Notes ...
Page 52: ...11620 54th Street North Clearwater FL 33760 727 573 9888 www GulfCoastSpas com ...